Chapter 2—Functional Descriptions
|
| Raster Timing Generator |
I/O | Description | |
IICDATA | Data line for transferring the following data (I = input, 0 = | |
| output). The input data are associated with an interrupt pulse. | |
| O | Priority Select |
| I | /Sync Select |
| I | Internal Sync |
| I | Horizontal Count |
| I | /Phase Lock |
| I | INTI |
| O | Vertical Flyback Start Delay |
| O | Map Start Delay |
| O | L Blank |
| O | R Blank |
| O | U Blank |
| O | D Blank |
| O | /STBP |
| O | DC Restore Delay |
| I | Phase Count |
| I | Correction Delay |
| I | Pincushion Start Delay |
|
|
|
Input | Description |
/IICINT | Interrupt used to tell the SCB that the RTG has data to report. |
/FRAMEST | Timing pulse Indicating the beginning of a frame. Used in the |
| SCB for counting vertical frequency. (TP5) |
/MAPST | Signal used to start the correction and overlay address counters |
| during each vertical sweep. (TP12) |
/Hx112 | Clock pulse at 112 times the horizontal frequency. Used for |
| convergence and |
/Hx224 | Square wave signal 224 times the horizontal frequency for |
| overlay map generation, horizontal map correction start, left |
| and right blanking, DC restore, and other timing functions. |
| (TP23) |
/FIELD1 | TTL level indicating which field of an interlaced frame (Low if |
| |
/CORRSTRT | Signal used to start the convergence and overlay address |
| generators during each horizontal sweep. (TP4) |
INTI | Indicates when input source signal is interlaced. (TP2) |
/VSYNC | Regenerated vertical sync signal, |
| lines in width. (TP21) |
|
|
|
|
Output | Description |
Model 330. 340SC, and 370SC Service Manual |