Chapter
Problem and | Possible Solution | Service | Operator | |
Symptom to |
|
| Manual | Manual |
Check |
|
|
|
|
|
|
|
|
|
Image out of focus |
|
|
|
|
Spacer balls not | Set projection lens focus so ILA® |
| 4.5 | |
visible. | spacer balls are visible. |
|
| |
ILA® Spacer balls | Adjust CRT Mechanical Focus. | 3.7 | 4.7.2 | |
visible but |
|
|
|
|
image fuzzy. |
|
|
|
|
CRT focus range is | Adjust electronic focus. | 3.8 | 4.7.3 | |
limited and |
|
|
|
|
image is fuzzy. |
|
|
|
|
CRT focus not | Set Relay Lens against back stop. |
|
| |
effective. |
|
|
|
|
CRT focus not | Ensure ILA® assembly is installed | 4.12 |
| |
effective. | correctly and clamps are snug. |
|
| |
CRT focus limited | Readjust fixed rod at upper left of | 3.7 |
| |
due to focus rod | CRT mounting bracket. |
|
| |
range. |
|
|
|
|
Image blurry with | Replace ILA® | Assembly. | 4.12 |
|
shadow on right |
|
|
|
|
edge. |
|
|
|
|
Characters do not | Replace ILA® | Assembly. | 4.12 |
|
appear legible. |
|
|
|
|
CRT focus problem | Replace CRT. |
| 4.7 |
|
limited to single |
|
|
|
|
color. |
|
|
|
|
G2 | Reset G2. |
| 3.10 |
|
Sensitivity offset set | Reset sensitivity offset. |
|
| |
too high. |
|
|
|
|
|
|
|
|
|
Picture geometry |
|
|
|
|
Picture not | Adjust using PHASE and POSITION. |
| 4.8 | |
centered. |
|
|
|
|
Picture size | Adjust using SIZE and BLANKING. |
|
| |
incorrect. |
|
|
|
|
Picture wrap around | Reset left or right BLANKING. |
|
| |
left or right |
|
|
|
|
edge. |
|
|
|
|
Retrace lines on | Reset TOP BLANKING. |
|
| |
raster. |
|
|
|
|
Model 330, 340SC, and 370SC Service Manual |