JVC 330, 370 SC, 340 SC service manual Second Set, Code, Description

Models: 340 SC 370 SC 330

1 163
Download 163 pages 51.75 Kb
Page 144
Image 144
Second Set

Chapter 5---Troubleshooting

STB +5volts or +24volts are still not present after verifying that the circuit breaker is on and the projector is plugged in, the System Power Supply may be defective.

NOTE: Only the +5 volts LED is lit on the Backplane Status Indicator panel (see Figure 2-2) when A/C power is applied. When the projector is directed to Power-On the +24volts standby LED should light and fans should be running.

2.If STB +5volts and +24volts are present, the SCB is the most likely cause of the problem.

Second Set

The second (2nd) set of operations only complete if no errors occur. If an error is detected, the code corresponding to the failed operation is displayed, and remains on the LED until the circuit breaker is cycled or another user “Power-On” command is issued. These errors are far more likely to occur than those of the first set.

Table 5-2Codes for Second Set of Operations (User "Power-On")

Code

Description

F“Lamp On” not detected.

E

SCB defective.

B

Low Voltage Power Supply output not detected.

 

 

9

SCB defective.

 

 

8

SCB defective.

 

 

7

SCB or RTG defective.

 

 

6

SCB defective.

 

 

5

SCB defective.

 

 

4

Any PCB in the Card Cage could be defective.

 

 

3

SCB defective.

 

 

2

SCB defective.

 

 

1

SCB defective.

 

 

0

All systems okay; start-up is finished. LED stays at 0 unless

the SCB receives an error signal that is listed in Table 5.1.

Model 330, 340SC, and 370SC Service Manual

5-4

Page 144
Image 144
JVC 330, 370 SC, 340 SC service manual Second Set, Code, Description