JVC 330, 370 SC, 340 SC Arc Lamp Current Adjustment, 9. Model 340SC and 370SC Arc Lamp Adjustments

Models: 340 SC 370 SC 330

1 163
Download 163 pages 51.75 Kb
Page 111
Image 111
Figure 3-9. Model 340SC and 370SC Arc Lamp Adjustments

Chapter 3---Service Adjustments

Figure 3-9. Model 340SC and 370SC Arc Lamp Adjustments

3.Verify that the condensing (collimating) lens assembly has not moved (see Figure 4-1 or 4-2 and Photo 4-4). Check to see if the assembly is loose. It should be unmovable in any direction.

4.The barrel of the lens assembly should be no more than 1½ inches (usually much closer) from the blue dichroic mirror. If it needs to be moved closer, first loosen the 3mm set screw located at the top of the mounting ring (Photo 4-4) that the barrel sets in, then move the lens closer to the blue dichroic mirror. This will increase the center brightness. Roll-off may not be acceptable if the barrel is moved too far forward.

NOTE: Be careful to maintain proper roll-off in these illumination optics (arc lamp and condensing lens) adjustments. It is possible to get very high brightness values at the screen center at the expense of proper roll-off. Try to keep the ratio between center brightness and edge brightness. Roll-off is 2:1 to the edge and 4:1 to the corners (e.g.: if the center brightness is 20 foot-candles, the edge brightness should be at least 10 foot-candles and preferably 10 foot-candles).

3.12Arc Lamp Current AdjustmentManual background CAUTION! Do not leave the roll-off at a value higher than 4:1, or the center may be too bright and could result in damage to the cold mirror.

5.Retighten the set screw.

3.12Arc Lamp Current Adjustment

The Arc Lamp current must be reset whenever an Arc Lamp is replaced and should be rechecked every 500 hours of Arc Lamp operation.

Manual backgroundManual background CAUTION! If the Arc Lamp current is being adjusted due to the installation of a new Arc Lamp or Arc Lamp/Ignitor assembly, the current adjust pot (Photo 4-3) must be turned to minimum (fully CCW). Failure to do this may result in damage to the equipment including failure of the Arc Lamp, Ignitor, or power supply.

To check and adjust the Arc Lamp current:

1.Measure the output voltage at the System Power Supply (SPS) Ignitor terminals J503 and J504. Note this figure.

Model 330, 340SC, 370SC Service Manual

3-21

Page 111
Image 111
JVC 330, 370 SC, 340 SC service manual Arc Lamp Current Adjustment, 9. Model 340SC and 370SC Arc Lamp Adjustments