B e fo r e C a l i b r a t i n g
Print Film Calibration Setup
The Print Film Calibration tab on the Setup window contains information that is required to obtain an accurate print film match.
Projector Aim:
Projector aim values specify the intended film projector open gate settings. Enter the values for the film projector you are emulating. If you have not characterized a specific projector, use the default values.
•White Luminance (Y) - Open gate luminance can be measured by a colorimeter or spectrophotometer. Enter the value in
•White Chromaticity (xy) - Open gate chromaticity can be measured by a colorimeter or spectrophotometer. Enter values in CIE xy.
•Projector SPD (Spectral Power Distribution) - Click this button to open a browse window where you can load a file that was created when measuring your projector with a spectroradiometer. This file should be a single column of values corresponding to measurements from
340 to 970 nm in 10 nm increments. Comment lines may be included in the file preceded by a # sign.
•Select Projector Aim Luminance Adjust to bring the brightness of the display down to the projector aim when simulating the print look. Deselect this option to keep the brightness at the Display Aim.
K O D A K D i s p l a y M a n a g e r S y s t e m V 4 . 1 U s e r ’ s G u i d e | 2 5 |