Tr o u b l e s h o o t i n g

Calibration Failure

Make sure that you are using a VGA monitor cable and that all the pins are present.

If the monitor settings need a lot of adjustment to reach aim, you may need to repeat the calibration process several times to bring the monitor into tolerances. To more quickly bring the monitor settings closer to aim, reset the monitor to factory defaults as described in your monitor user manual.

Track the progress of each calibration by observing the Current and Target Values displayed on the Calibration window. Repeat the calibration process as many times as necessary as long as the calibration points continue to move toward aim. If the points stop moving or they oscillate above and below aim, you may need to replace your monitor. Contact your support representative.

When repeating a failed calibration, make sure that the:

Room is dimly lit or a dark cloth is placed over the monitor

Sensor is securely attached to the monitor if the sensor has suction cups

Enable cable and sensor connections are properly made

Dark Gain Correction of the sensor is performed correctly

Monitor is warmed up properly

Monitor is a type that is supported for auto-calibration

Monitor is in Expert mode, if available

Super Bright mode is disabled, if available

Picture effect is set to Dynamic, if available

Timing for reading patches is set properly. We recommend that you use the default settings. If you have shortened the timing to increase calibration speed, the readings from the sensor may have some erroneous points. Go to Options > Setup. From the Times tab, set Colors to 4 and Patches to 1.

Make sure to uninstall any other monitor calibration software that you might have on your system.