Tr o u b l e s h o o t i n g
Imaging Product Cannot Find LUT
If your imaging product cannot find the LUT that you created from the Viewer:
•Make sure you have the proper path set. Go to Options > Setup and from the Directories tab set the path.
•Make sure your imaging product is supported by the Display Manager System.
•Refer to your imaging product user guide for directions on LUTs generated by the Display Manager System.
My 1D LUT Does Not Match my 3D LUT
1D LUTs provide a tonescale emulation of the projected print film. 3D LUTs provide both tonescale and color emulations.
My Wide Color Gamut Encoded LUT Does Not Look Correct
Wide Color Gamut encoded LUTs imported to the viewer will not look correct. These LUTs are not intended for preparing an image for display on a computer monitor.
Problem with the .ini File
When opening the Display Manager System, you may see an error message for the .ini file if you have not yet saved any settings for the first time.
If you have saved your settings but you still get a message that there is a problem with the .ini file:
1.Click OK.
The system opens using the factory defaults for any unknown values.
2.Reset and save your system options. See “Saving and Loading Settings” on page 30.
3.If necessary, reset and save your Viewer settings. See “Viewing and Customizing Looks” on page 49.