Configuring the SPA932

Using the SPA932 Sidecar

Setting Up the SPA932 Sidecar

Configuring the SPA932

Complete the configuration required for the extensions on your IP PBX and obtain the following information:

SPA9000 IP address or other hostname

Phone extension numbers

To configure the SPA932:

1.Connect to the web UI for the SPA962 to which the SPA932 is connected.

2.Click Admin/Advanced on the web UI page.

3.Click the SIP tab.

4.Select yes from the CTI Enable drop-down list.

5.Click the SPA932 tab. (If you do not see the SPA932 tab, check your firmware version, and upgrade as necessary.)

The system displays the SPA932 web page.

6.Select yes from the Unit 1 Enable drop-down list. If you have installed two SPA932 units, also select yes from the Unit 2 Enable drop-down list.

7.Select your Server Type from the drop-down list:

SPA9000

Broadsoft

Asterisk

8.Make sure that no is selected for Test Mode Enable. This option is disabled by default. You cannot complete the software configuration for the SPA932 if this option is enabled. (You can use Test Mode Enable later to test the SPA932.)