Linksys SPA922, SPA962, SPA942, SPA932 SIP Timer Values, SIP Timer Notes, Setting SIP Parameters

Models: SPA942

1 196
Download 196 pages 29.34 Kb
Page 55
Image 55
SIP Timer Values

Setting SIP Parameters

SIP Timer Values

Parameter

Description

 

 

Caller ID Header

Select where the SPA9x2 gets its caller ID from:

 

PAID-RPID-FROM

 

P-ASSERTED-IDENTITY

 

REMOTE-PARTY-ID

 

FROM header

 

Defaults to PAID-RPID-FROM

 

 

SIP Timer Values

SIP timer values control transmittal, time-out, delay intervals and so on for SPA9x2 data. Each value is displayed in seconds.

SIP Timer Notes

Register Retry Enhancements: this feature adds flexibility to the delay timers that are activated when the SIP REGISTER of a device fails. Timers are selected based on the failure response code sent by the SIP proxy. Depending on the type of registration failure, either a short timer or a long timer is activated.

All SIP timer parameters are included in the following table.

Parameter

Description

 

 

SIP T1

RFC 3261 T1 value (RTT estimate). Ranges from 0 to 64 seconds.

 

Defaults to .5 seconds.

 

 

SIP T2

RFC 3261 T2 value, which is the maximum retransmit interval for non-

 

INVITE requests and INVITE responses. Ranges from 0 to 64 seconds.

 

Defaults to 4 seconds.

 

 

Linksys SPA9x2 Phone Administration Guide

48

Page 55
Image 55
Linksys SPA922, SPA962, SPA942, SPA932 manual SIP Timer Values, SIP Timer Notes, Setting SIP Parameters