Response Status Code Handling

Setting SIP Parameters

Response Status Code Handling

Parameter

Description

 

 

Reg Retry Random

Random delay added to the Register Retry Intvl value when retrying

Delay

REGISTER after a failure. Minimum and maximum random delay to be

 

added to the short timer.

 

Defaults to 0, which disables this feature.

 

 

Reg Retry Long

Random delay add ed to Register Retry Long Intvl value when retrying

Random Delay

REGISTER after a failure. Reg_Retry_Long_Random_Delay—

 

Minimum and maximum random delay to be added to the long

 

timer. Random delay range (in seconds) to add to the Register Retry

 

Long Intvl when retrying REGISTER after a failure.

 

Defaults to 0, which disables this feature.

 

 

Reg Retry Intvl Cap

Reg_Retry_Intvl_Cap—Maximum value of the exponential delay. The

 

maximum value to cap the exponential backoff retry delay (which starts at

 

the Register Retry Intvl and doubles every retry).

 

Defaults to 0, which disables the exponential backoff feature (that is, the

 

error retry interval is always at the Register Retry Intvl). If this feature is

 

enabled, the Reg Retry Random Delay is added on top of the exponential

 

backoff delay value.

 

 

Sub Min Expires

The lower limit of the REGISTER (suscribe) expires value returned from the

 

proxy server.

 

Defaults to 10 seconds.

 

 

Sub Max Expires

The upper limit of the REGISTER (subscribe) min-expires value returned

 

from the proxy server in the Min-Expires header.

 

Defaults to 7200 seconds.

 

 

Sub Retry Intvl

The retry interval when the last Subscribe request fails.

 

Defaults to 10 seconds.

 

 

NOTE: SPA9x2 phones can use a RETRY-AFTER value when received from a SIP proxy server that is too busy to process a request (503 Service Unavailable message). If the response message includes a RETRY-AFTER header, the phone waits for the specified length of time before retrying to REGISTER again. If a RETRY-AFTER header is not present, the phone waits for the value specified in the Reg Retry Interval or the Reg Retry Long Interval parameter.