SPA9x2 Phone Field Reference

Phone Tab

Parameter

Description

 

 

Local Progressing LED

LED pattern during the Local Progressing state, where

 

this station is attempting on this call appearance an

 

outgoing call that is in proceeding (i.e. the called

 

number is ringing). Leaving this entry blank indicates the

 

default value of c=r.

 

 

Remote Progressing LED

LED pattern during the Remote Progressing state, where

 

another station is attempting on this shared call

 

appearance an outbound call that is progressing. Not

 

applicable if the call appearance is not shared. Leaving

 

this entry blank indicates the default value of c=r;p=d.

 

 

Local Ringing LED

LED pattern during the Local Ringing state, when the call

 

appearance is ringing. Leaving this entry blank indicates

 

the default value of c=r;p=f.

 

 

Remote Ringing LED

LED pattern during the Remote Ringing state, where the

 

shared call appearance is in ringing on another station.

 

Not applicable if the call appearance is not shared.

 

Leaving this entry blank indicates the default value of

 

c=r;p=d.

 

 

Local Active LED

LED pattern during the Local Active state, where the call

 

appearance is engaged in an active call. Leaving this

 

entry blank indicates the default value of c=r.

 

 

Remote Active LED

LED pattern during the Remote Active state, where

 

another station is engaged in an active call on this

 

shared call appearance. Not applicable is this call

 

appearance is not shared. Leaving this entry blank

 

indicates the default value of c=r;p=d.

 

 

Local Held LED

LED pattern during the Local Held state, where the call

 

appearance is held by this station. Leaving this entry

 

blank indicates the default value of c=r;p=s.

 

 

Remote Held LED

LED pattern during the Remote Held state, where

 

another station has placed this call appearance on hold.

 

Not applicable if the call appearance is not shared.

 

Leaving this entry blank indicates the default value of

 

c=4,p=s.

 

 

Register Failed LED

LED pattern when the corresponding extension has

 

failed to register with the proxy server. Leaving this entry

 

blank indicates the default value of c=a.

 

 

Disabled LED

LED pattern when the Call Appearance is disabled (not

 

available for any incoming or outgoing call). Leaving this

 

entry blank indicates the default value of c=o.

 

 

Linksys SPA9x2 Phone Administration Guide

159

Page 166
Image 166
Linksys SPA932 Remote Progressing LED, Another station is attempting on this shared call, Local Ringing LED, =rp=d, =4,p=s