Setting Regional Parameters

Advanced Scripting for Cadences, Call Progress Tones, and Ring Tones

Example 1: Dial Tone

350@-19,440@-19;10(*/0/1+2)

Number of Frequencies = 2

Frequency 1 = 350 Hz at –19 dBm

Frequency 2 = 440 Hz at –19 dBm

Number of Cadence Sections = 1

Cadence Section 1: Section Length = 10 s

Number of Segments = 1

Segment 1: On=forever, with Frequencies 1 and 2

Total Tone Length = 10s

Example 2: Stutter Tone

350@-19,440@-19;2(.1/.1/1+2);10(*/0/1+2)

Number of Frequencies = 2

Frequency 1 = 350 Hz at –19 dBm

Frequency 2 = 440 Hz at –19 dBm

Number of Cadence Sections = 2

Cadence Section 1: Section Length = 2s

Number of Segments = 1

Segment 1: On=0.1s, Off=0.1s with Frequencies 1 and 2

Cadence Section 2: Section Length = 10s

Number of Segments = 1

Segment 1: On=forever, with Frequencies 1 and 2

Total Tone Length = 12s