Control Timer Values (sec)

SPA9x2 Phone Field Reference

Regional Tab

Control Timer Values (sec)

Parameter

Description

 

 

Reorder Delay

Delay after far end hangs up before reorder tone is

 

played. 0 = plays immediately, inf = never plays. Range:

 

0–255 seconds.

 

Defaults to 255.

 

 

Call Back Expires

Expiration time in seconds of a call back activation.

 

Range: 0–65535 seconds.

 

Defaults to 1800.

 

 

Call Back Retry Intvl

Call back retry interval in seconds. Range: 0–255

 

seconds.

 

Defaults to 30.

 

 

Call Back Delay

Delay after receiving the first SIP 18x response before

 

declaring the remote end is ringing. If a busy response is

 

received during this time, the SPA9x2 still considers the

 

call as failed and keeps on retrying.

 

Defaults to 0.5.

 

 

Interdigit Long Timer

Long timeout between entering digits when dialing. The

 

interdigit timer values are used as defaults when dialing.

 

The Interdigit_Long_Timer is used after any one digit, if

 

all valid matching sequences in the dial plan are

 

incomplete as dialed. Range: 0–64 seconds.

 

Defaults to 10.

 

 

Interdigit Short Timer

Short timeout between entering digits when dialing. The

 

Interdigit_Short_Timer is used after any one digit, if at

 

least one matching sequence is complete as dialed, but

 

more dialed digits would match other as yet incomplete

 

sequences. Range: 0–64 seconds.

 

Defaults to 3.

 

 

Vertical Service Activation Codes

The following Vertical Service Activation Codes are automatically appended to the dial-plan.