OMNIDIAGNOSTICS™
Logicube Omniclone Xi ™ User’s Manual 29
Repair Target Mode Step-by-Step
1. From anywhere in the menu system, press the
Set button to enter the Settings menu.
2. Press the Cloning Mode icon that appears in the
upper left-hand corner. A list of the available
cloning modes appears.
3. Press the“Repair” icon, the Repair Target™
settings screen will appear.
4. You may now double-click the“Start/Stop”
button to start cloning. You will be warned that
continuing will modify yourDestination drive. If
you are ready to do this, choose “Yes” to
continue.
5. When finished, the Logicube Omniclone Xi™ will
notify you and display a list of the scanned
drives along with bad, weak and repaired
sectors found on each drive.
6. After reviewing the summary, touch the Back
icon to return to the main menu.
WipeClean™ Target Mode
The WipeClean™ Target mode erases all data on
the Target drives. This may be required when
discarding drives that contain sensitive information
to which you do not want others to have access,
e.g. financial information, trade secrets, etc.
WipeClean™ writes a pattern over the whole Target
drive 2 X n+1 times, where n is the selected
number of iterations of all 0’s and all 1’s. The last
pass then writes the chosen pattern to every byte of
the drive.
For example, if you set the Value to “0xff” and the
number of iterations (the value of n in the above
formula) to 1, WipeClean™ will perform a total of
three passes, first writing all 0’s then again writing
all 1’s. Then one more pass will be made that
leaves a repeating “FF” pattern.
By default, WipeClean™ is set to erase data
according to Department of Defense (DoD)
specification M-5220. This setting is 3 passes and
a final pattern of “0xF6”.
Set the number of passes to 0 for a single pass of
the chosen pattern. This method is acceptable for