USER REPLACEABLE HARDWARE
48 Logicube Omniclone Xi User’s Manual
Power Supply
The OCXi and OCX5i models have an internal
power supply that can also be replaced by the user.
When it is determined that the power supply needs
to be replaced, please follow the procedure below:
Replacement Power Supplies are available from
Logicube. Please contact Logicube Sales for more
information.
NOTE: The Omniclone OCX2i uses a separate
power supply that is not physically connected to the
unit.
Removal and Installation of the Power Supply
1. Remove the AC Power Cord from the power
supply.
2. Remove the two screws located on either
side of the Power Supply.
3. Turn the unit over and remove the six screws
that hold the power supply to the bottom of
the unit.
4. Lift up on the power supply module to remove
it from the unit.
5. Disconnect the cable harness from the main
circuit board.
6. Installation of the Power Supply is the
opposite of removal.