CLONING MODES AND SETTINGS

Optional Preference Settings

In addition the different cloning modes, there are preference settings that can be used to adjust the behavior of the cloning operation. Each of these preference settings is accessible through the Settings menu, which can viewed at any time from anywhere in the menu system by pressing the Set button.

NOTE: Not all preference settings are available in every cloning mode.

Verify

The Verify preference allows you to choose whether the Logicube Omniclone Xi™ verifies the data copied to the Target drive. Verify also scans the Target drives for bad or weak sectors. With Verify activated, data written to the Target is read back sector by sector and compared against the original data on the Master. If a bad sector of data is detected, the cloning process is aborted.

Verify Settings

No Verify (Default) - No data verification is performed.

1% Verify - Only the first 1% of the data sectors are verified. This is faster but less thorough than using the All setting.

100% Verify - Every data sector on the Target drive to which data has been written is checked.

NOTE: Logicube strongly recommends against using a hard drive that has been shown to have bad sectors as new defects are likely to develop.

20

Logicube Omniclone Xi ™ User’s Manual

Page 26
Image 26
Logicube Omniclone Xi user manual Optional Preference Settings, Verify Settings