USER REPLACEABLE HARDWARE

Proper Handling of Drive Cables

UDMA Cables – When removing the cable from a drive, be sure to pull on the white tab that is attached to the head. DO NOT pull on the cable itself as this will diminish cable life.

Power cables – Remove the cable from the drive by gripping the white plastic head firmly and pulling straight out. Do NOT pull on the wires as this will damage the cable.

SATA Cables – Remove the cable from the drive by gripping the black plastic head firmly and pulling straight out. DO NOT twist or pull by the cable as this will shorten cable life.

Drive Stations

The “Drive Stations” of the Omniclone Xi™ refer to the connection plates of each Master and Target position. These plates are very rugged and able to withstand thousands of cloning sessions. However, damaged or incorrectly connected drives can damage the Drive Station. When this occurs, the station can be easily replaced by the user.

Replacement Drive Station Modules are available from Logicube. Please contact Logicube Sales for more information.

Removal and Installation of a Drive Station

1.Turn off the power to the unit and unplug the power supply cord.

2.Remove the drive and any cables from the non-functional Drive Station.

3.Loosen the two thumb-screws located on either side of the Drive Station.

4.Pull straight up on the thumb-screws, the Drive Station should come right out.

5.Installation of the Drive Station is the opposite of removal.

Logicube Omniclone Xi ™ User’s Manual

47

Page 53
Image 53
Logicube Omniclone Xi Proper Handling of Drive Cables, Drive Stations, Removal and Installation of a Drive Station