quickly wiping a drive where removal of sensitive
information is not an issue.
WipeClean™ Settings
The following settings are used in configuring
WipeClean™ Target mode:
Passes – Determines how many passes of all 0’s
and all 1’s are written to the drive. The default is 1
for compliance with DoD M-5220.
Value – Select the value to be written on the last
pass. The options are 0xf6, 0x00, 0xff, and Random
(DoD default). (The Random setting will fill the
Target drive with a pseudo random pattern.)
Speed – The speed can be manually set from
UDMA 5 to PIO-SLOW.
NOTE: The unit will run at the fastest possible
speed as long as a drive is attached to the Master
position. This should not be an actual Master drive
as a pattern will be written to part of the drive and it
will be rendered unbootable.
If no drive is attached to the Master position the unit
will still wipe the Target drives, but it will run at
speeds ranging from 60 – 100 MB/min.
Wipeclean™ Target Step-by-Step
1. From anywhere in the menu system, press the
Set button to enter the Settings menu.
2. Press the Cloning Mode icon that appears in the
upper left-hand corner. A list of the available
cloning modes appears.
3. Press the “WipeOut” icon, the Wipeclean
Target™ settings screen will appear.
4. Touch the Passes” icon to set the number of
passes. Use the numeric keypad to enter the
number of passes. Press OK when finished.
5. Touch the Value” icon to scroll through the
different patterns.
6. Touch the “Speed” icon to choose the best
speed, if necessary.
NOTE: The unit will automatically adjust itself to
the best speed for the attached drives.
7. Press the Start/Stop button twice.