THE DATABASE/BARCODE OPTION
Logicube Omniclone Xi ™ User’s Manual 35
We can see from this example that a Master drive
was cloned to a single Target drive on May 18,
2005. Mirror Clone mode was used and the cloning
session completed successfully.
NOTE: Thedatabase.csv file will continue to
receive data from cloning sessions until it is
renamed or deleted, at which point a new
database.csv file will be created. If you need to
change Config Lists, make sure that you rename or
remove the olddatabase.csv file from the CF drive.
Database Step–by-Step
NOTE: This procedure goes from attaching the
Barcode Scanner to choosing a Config List to
running the cloning session and collecting the
database.csv file. It is a basic rundown of the
Database process. Details such as the menu
options and the Barcode Scanner will be discussed
later in the chapter.
1. Attach the Barcode Scanner to the PS/2 Port
on the front of the Omniclone-Xi unit.
2. Insert the Compact Flash (CF) Drive in the
CF Slot and power up the unit.
3. From the Main Screen, press theSet button.
4. Touch theGeneral Preferences icon in the
Lower left-hand corner of the screen.
5. Touch theDatabase icon. This will open the
Database Settings Menu.
NOTE: If the Database/Barcode option is not
enabled, a warning message will appear and the
Database Menu will not open.
6. Touch theSelect Config icon. It will bring up
all of the Config Lists that are stored in the
Config.txt file that is on the CF Drive.
7. Touch the desired Config List. A check mark
will appear next to it. TouchOK.
NOTE: Once a Config List is chosen, the name of
the list will appear at the top of the Database Menu.
8. Touch theDatabase icon to set it to ON, (the
default is OFF).
9. Touch theBack icon twice to go back to the
Cloning Settings Menu. Change the settings
as desired.
10. PressST ART/STOP to begin cloning.