Chapter 6 Cajun Campus CLI – Layer 2

interval

The interval between 2 samples

number of buckets

The number of buckets defined

owner name

Owner name string

Example:

Cajun_P330-N# rmon history 1026 1026 interval 30 buckets 20 owner amir

history 1026 was created successfully

Rmon alarm Command

Use the rmon alarm command to create a new RMON alarm entry.

The syntax for this command is:

rmon alarm <Alarm Number> <variable> <interval> <sampletype> rising-threshold<rising threshold> <rising event> falling- threshold <falling threshold> <falling event> <startup alarm> <owner>

alarm

This is the alarm index number of this entry (it is advisable to use

number

the same interface number as your alarm index number.)

variable

This is the MIB variable which will be sampled by the alarm entry.

interval

The interval between 2 samples

sample

This can be set to either delta (the difference between 2 samples)

type

or an absolute value.

rising

This sets the upper threshold for the alarm entry.

threshold

 

rising

The RMON event entry that will be notified if the upper threshold

event

is passed.

falling

This sets the lower threshold for the alarm entry.

threshold

 

falling

The RMON event entry that will be notified if the lower threshold is

event

passed.

startup

The instances in which the alarm will be activated. The possible

alarm

parameters are: Rising, Falling, risingOrfalling.

90

Cajun P332MF User’s Guide

Page 104