Chapter 6 Cajun Campus CLI – Layer 2

Show snmp Command

Use the show snmp command to display SNMP information.

The syntax for this command is:

show snmp

Example:

Cajun_P330-N> show snmp

Authentication trap disabled

Community-Access

Community-String

----------------

----------------

read-only

public

read-write

public

trap

public

Trap-Rec-Address

Traps Enabled

----------------

----------------

1.1.1.1

config

 

fault

 

etc...

Show snmp retries Command

Use the show snmp retries command to display the number of retries initiated by the Device Manager application when it tries to send SNMP messages to the device.

The syntax for this command is:

show snmp retries

Example:

Cajun_P330-N> show snmp retries the SNMP Retries Number is 3

Show snmp timeout Command

Use the show snmp timeout command to display the default SNMP timeout in seconds. This command is useful for access using the Device Manager.

The syntax for this command is:

show snmp timeout

Cajun P332MF User’s Guide

43

Page 57
Image 57