Chapter 2

Cajun P332MF Front and Back Panels

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 2.1

Cajun P332MF LED Descriptions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED Name

 

 

Description

LED Status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF – No Flow Control only and/or while in

 

 

 

 

 

Symmetric Flow

half duplex mode

 

 

 

FC

 

 

 

 

 

 

 

 

 

ON – Symmetric/Asymmetric Flow Control

 

 

 

 

Control

 

 

 

 

 

 

 

 

 

 

mode is enabled and port is in full duplex

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hspd

 

 

High Speed

 

10/100

1000

 

 

 

 

 

 

 

OFF:

10

N/A

 

 

 

 

 

 

 

ON:

100

1000

 

 

 

 

 

 

 

 

 

 

LAG

 

 

Link Aggregation

OFF – No LAG defined for this port

 

 

 

 

 

 

 

 

 

 

 

Group (Trunking)

ON – Port belongs to a LAG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 2.2

Cajun P330 <- -> Select buttons

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description

 

 

 

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Left/Right

 

 

 

Individual – select LED function (see table above).

 

 

 

 

 

 

 

Reset module

 

Press both right and left buttons together for approximately two

 

 

 

 

 

 

seconds. All LEDs on module light up until buttons are released.

 

 

 

 

 

 

 

 

 

Reset stack

 

 

 

Press both right and left buttons together for 4 seconds. All

 

 

 

 

 

 

LEDs on stack light up until buttons are released.

 

 

 

 

 

 

 

 

 

FIV

 

 

 

Force Initial Version – boot from backup initial version of the

 

 

 

 

 

 

Cajun P330 software, from Bank A (see Note below).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: To perform “Force Initial Version” reset the module and at the same time press the FIV reset button (use an opened paper clip or other pointed object). Release the reset buttons first and 1 or 2 seconds later, release the FIV button.

Note: The Port LEDs of the P332MF are numbered from 1-12. Expansion sub- module ports are numbered from 51. Port LED numbers 49-50 are reserved.

10

Cajun P332MF User’s Guide

Page 24
Image 24
Lucent Technologies P332MF manual Off