Electrical Specifications

AC Electrical Specifications

8.6.14Transport Stream (TS) Interface AC Timing

8.6.14.1Transport Stream Interface AC Timing Table

Table 62: Transport Stream Output Interface AC Timing Table

Description

Symbol

Min

Max

Units

Notes

Clock frequency

fCK

See note 1

MHz

1

Clock minimum low level w idth

tLOW

0.4

0.6

tCK

2

Clock minimum high level w idth

tHIGH

0.4

0.6

tCK

2

Data output valid after Clock rising edge

tOV

0.4

0.6

tCK

2, 3

Notes:

General comment: All values w ere measured from VIL(max) to VIH(min), unless otherw ise specified.

General comment: tCK = 1/fCK.

1.See "Reference Clocks" table for more details.

2.For all signals, the load is CL = 5 pF.

3.When configured to falling edge, the tOV parameter is relative to Clock falling edge.

Table 63: Transport Stream Input Interface AC Timing Table

Description

Symbol

Min

Max

Units

Notes

Clock frequency

fCK

See note 1

MHz

1

Clock minimum low level w idth

tLOW

0.35

0.65

tCK

-

Clock minimum high level w idth

tHIGH

0.35

0.65

tCK

-

Data input setup time relative to Clock rising edge

tSU

0.30

-

tCK

2

Data input setup time relative to Clock rising edge

tHD

0.30

-

tCK

2

Notes:

General comment: All values w ere measured from VIL(max) to VIH(min), unless otherw ise specified.

General comment: tCK = 1/fCK.

1.See "Reference Clocks" table for more details.

2.When configured to falling edge, the tSU/tHD parameters are relative to Clock falling edge.

Copyright © 2008 Marvell

 

Doc. No. MV-S104859-U0 Rev. E

December 2, 2008, Preliminary

Document Classification: Proprietary Information

Page 115

Page 115
Image 115
Marvel Group 88F6281 specifications Transport Stream TS Interface AC Timing, Transport Stream Interface AC Timing Table