Pin and Signal Descriptions

Pin Descriptions

1.2.19Transport Stream (TS) Interface

„All of the TS signals are multiplexed on the MPP pins (see Section 4, Pin Multiplexing, on page 51).

„The TS signals are powered on VDDO or on VDD_GE_B based on the pin

Note multiplexing option (see Section 4, Pin Multiplexing ).

Table 21: Transport Stream (TS) Interface Signal Assignment

Pin Name

I/O

Pin Type

Power Rail

Description

TSMP[0]

I

CMOS

VDDO/

EXT_CLK

 

 

 

VDD_GE_B

External clock that can be used to drive the TS0_CLK and

 

 

 

 

TS1_CLK

TSMP[1]

I/O

CMOS

VDDO/

TS0_CLK

 

 

 

VDD_GE_B

Port0 TS clock.

 

 

 

 

• If TS0_VAL is used, the clock may be continuous.

 

 

 

 

• If TS0_VAL is not used, the clock may toggle only when valid

 

 

 

 

 

data is available on TS0_DATA.

TSMP[2]

I/O

CMOS

VDDO/

TS0_SYNC

 

 

 

VDD_GE_B

Port0 Sync/Frame Start Indicator or Packet Clock.

 

 

 

 

The TS0_SYNC in parallel mode is a pulse that is active during

 

 

 

 

the first (Sync) byte of the TS packet. In serial mode, the

 

 

 

 

TS0_SYNC pulse may be active for the entire byte or only for the

 

 

 

 

first bit. The polarity is programmable to be either active high or

 

 

 

 

active low.

TSMP[3]

I/O

CMOS

VDDO/

TS0_VAL

 

 

 

VDD_GE_B

Port0 Valid Data Indicator

 

 

 

 

When this signal is used and is valid, it indicates that valid data is

 

 

 

 

present on TS0_DATA. TS0_VAL is active during the TS frame

 

 

 

 

packet data and inactive when there is no TS synchronization.

 

 

 

 

In output mode, the polarity of TS0_VAL is programmable to be

 

 

 

 

either active high or active low.

TSMP[4]

I/O

CMOS

VDDO/

TS0_ERR

 

 

 

VDD_GE_B

Port0 Uncorrectable Packet Error

 

 

 

 

When this signal is used, an error indicates that the packet

 

 

 

 

contains an uncorrectable error, and therefore should not be

 

 

 

 

used.

 

 

 

 

In output mode, the TS0_ERR is active during the entire TS

 

 

 

 

frame.

TSMP[5]

I/O

CMOS

VDDO/

TS0_DATA[0]

 

 

 

VDD_GE_B

Port0 TS Data bit 0 in both parallel and serial modes.

 

 

 

 

In Serial mode TS0_DATA[0] is used as data input or output.

TSMP[6]

I/O

CMOS

VDDO/

Parallel Mode:

 

 

 

VDD_GE_B

 

TS0_DATA[1]: Port0 TS Data bit 1

 

 

 

 

Serial Mode:

 

 

 

 

 

TS1_CLK: Port1 TS clock.

 

 

 

 

 

- If TS1_VAL is used, the clock may be continuous.

 

 

 

 

 

- If TS1_VAL is not used, the clock may toggle only when

 

 

 

 

 

valid data is available on TS1_DATA

 

 

 

 

 

 

Copyright © 2008 Marvell

 

Doc. No. MV-S104859-U0 Rev. E

December 2, 2008, Preliminary

Document Classification: Proprietary Information

Page 45

Page 45
Image 45
Marvel Group 88F6281 specifications Transport Stream TS Interface Signal Assignment