Product Preview

DS21Q55

DS21552

0002h

31.2 Test Registers

IEEE 1149.1 requires a minimum of two test registers: the bypass register and the boundary scan register. An optional test register has been included with the DS2155 design. This test register is the identification register and is used with the IDCODE instruction and the test- logic-reset state of the TAP controller.

31.3 Boundary Scan Register

This register contains both a shift register path and a latched parallel output for all control cells and digital I/O cells and is n bits in length. See Table 34-4 for all of the cell bit locations and definitions.

31.4 Bypass Register

This is a single 1-bit shift register used with the BYPASS, CLAMP, and HIGH- Z instructions that provides a short path between JTDI and JTDO.

31.5 Identification Register

The identification register contains a 32-bit shift register and a 32-bit latched parallel output. This register is selected during the IDCODE instruction and when the TAP controller is in the test- logic-reset state. See Tables 34-2 and 34-3 for more information about bit usage.

205 of 248

012103

Please contact telecom.support@dalsemi.com or search http://www.maxim-ic.com for updated

information.

Page 205
Image 205
Maxim DS21Q55 specifications Test Registers, Boundary Scan Register, Bypass Register, Identification Register