Product Preview

 

 

 

 

 

 

 

DS21Q55

Register Name:

BC2

 

 

 

 

 

 

 

Register Description:

BERT Control Register 2

 

 

 

 

 

Register Address:

E1h

 

 

 

 

 

 

 

Bit #

7

6

5

4

3

2

1

0

 

Name

EIB2

EIB1

EIB0

SBE

RPL3

RPL2

RPL1

RPL0

 

Default

0

0

0

0

0

0

0

0

 

Bits 0 to 3/Repetitive Pattern Length Bit 3 (RPL0 to RPL3). RPL0 is the LSB and RPL3 is the MSB of a nibble that describes the how long the repetitive pattern is. The valid range is 17 (0000) to 32 (1111). These bits are ignored if the receive BERT is programmed for a pseudorandom pattern. To create repetitive patterns less than 17 bits in length, the user must set the length to an integer number of the desired length that is less than or equal to 32. For example, to create a 6-bit pattern, the user can set the length to 18 (0001) or to 24 (0111) or to 30 (1101).

Length (Bits)

RPL3

RPL2

RPL1

RPL0

17

0

0

0

0

18

0

0

0

1

19

0

0

1

0

20

0

0

1

1

21

0

1

0

0

22

0

1

0

1

23

0

1

1

0

24

0

1

1

1

25

1

0

0

0

26

1

0

0

1

27

1

0

1

0

28

1

0

1

1

29

1

1

0

0

30

1

1

0

1

31

1

1

1

0

32

1

1

1

1

Bit 4/Single Bit Error Insert (SBE). A low-to-high transition will create a single bit error. Must be cleared and set again for a subsequent bit error to be inserted.

Bits 5 to 7/Error Insert Bits 0 to 2 (EIB0 to EIB2). Will automatically insert bit errors at the prescribed rate into the generated data pattern. Can be used for verifying error detection features.

EIB2

EIB1

EIB0

ERROR RATE INSERTED

0

0

0

No errors automatically inserted

0

0

1

10E-1

0

1

0

10E-2

0

1

1

10E-3

1

0

0

10E-4

1

0

1

10E-5

1

1

0

10E-6

1

1

1

10E-7

179 of 248

012103

Please contact telecom.support@dalsemi.com or search http://www.maxim-ic.com for updated

information.

Page 179
Image 179
Maxim DS21Q55 specifications BC2, E1h, Length Bits, RPL3 RPL2 RPL1 RPL0, EIB2 EIB1 EIB0 Error Rate Inserted