Product Preview

 

 

 

 

 

 

DS21Q55

 

Register Name:

RS1 to RS16

 

 

 

 

 

 

Register Description:

Receive Signaling Registers (E1 Mode, CAS Format)

 

 

 

Register Address:

60h to 6Fh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(MSB)

 

 

 

 

 

 

(LSB)

 

 

0

0

0

0

X

Y

X

X

RS1

 

CH2-A

CH2-B

CH2-C

CH2-D

CH1-A

CH1-B

CH1-C

CH1-D

RS2

 

CH4-A

CH4-B

CH4-C

CH4-D

CH3-A

CH3-B

CH3-C

CH3-D

RS3

 

CH6-A

CH6-B

CH6-C

CH6-D

CH5-A

CH5-B

CH5-C

CH5-D

RS4

 

CH8-A

CH8-B

CH8-C

CH8-D

CH7-A

CH7-B

CH7-C

CH7-D

RS5

 

CH10-A

CH10-B

CH10-C

CH10-D

CH9-A

CH9-B

CH9-C

CH9-D

RS6

 

CH12-A

CH12-B

CH12-C

CH12-D

CH11-A

CH11-B

CH11-C

CH11-D

RS7

 

CH14-A

CH14-B

CH14-C

CH14-D

CH13-A

CH13-B

CH13-C

CH13-D

RS8

 

CH16-A

CH16-B

CH16-C

CH16-D

CH15-A

CH15-B

CH15-C

CH15-D

RS9

 

CH18-A

CH18-B

CH18-C

CH18-D

CH17-A

CH17-B

CH17-C

CH17-D

RS10

 

CH20-A

CH20-B

CH20-C

CH20-D

CH19-A

CH19-B

CH19-C

CH19-D

RS11

 

CH22-A

CH22-B

CH22-C

CH22-D

CH21-A

CH21-B

CH21-C

CH21-D

RS12

 

CH24-A

CH24-B

CH24-C

CH24-D

CH23-A

CH23-B

CH23-C

CH23-D

RS13

 

CH26-A

CH26-B

CH26-C

CH26-D

CH25-A

CH25-B

CH25-C

CH25-D

RS14

 

CH28-A

CH28-B

CH28-C

CH28-D

CH27-A

CH27-B

CH27-C

CH27-D

RS15

 

CH30-A

CH30-B

CH30-C

CH30-D

CH29-A

CH29-B

CH29-C

CH29-D

RS16

85 of 248

012103

Please contact telecom.support@dalsemi.com or search http://www.maxim-ic.com for updated

information.

Page 85
Image 85
Maxim DS21Q55 RS1 to RS16, Receive Signaling Registers E1 Mode, CAS Format, 60h to 6Fh, CH9-A CH9-B CH9-C CH9-D RS6