Product Preview

DS21Q55

25.3 BERT Bit Counter

Once BERT has achieved synchronization, this 32-bit counter will increment for each data bit (i.e., clock) received. Toggling the LC control bit in BC1 can clear this counter, which saturates when full and will set the BBCO status bit.

Register Name:

BBC1

Register Description:

BERT Bit Count Register 1

Register Address:

E3h

Bit #

Name

Default

7

6

5

4

3

2

1

0

BBC7

BBC6

BBC5

BBC4

BBC3

BBC2

BBC1

BBC0

0

0

0

0

0

0

0

0

Bits 0 to 7/BERT Bit Counter Bits 0 to 7 (BBC0 to BBC7). BBC0 is the LSB of the 32-bit counter.

Register Name:

BBC2

Regis ter Description:

BERT Bit Count Register 2

Register Address:

E4h

Bit #

Name

Default

7

6

5

4

3

2

1

0

BBC15

BBC14

BBC13

BBC12

BBC11

BBC10

BBC9

BBC8

0

0

0

0

0

0

0

0

Bits 0 to 7/BERT Bit Counter Bits 8 to 15 (BBC8 to BBC15).

Register Name:

BBC3

Register Description:

BERT Bit Count Register 3

Register Address:

E5h

Bit #

Name

Default

7

6

5

4

3

2

1

0

BBC23

BBC22

BBC21

BBC20

BBC19

BBC18

BBC17

BBC16

0

0

0

0

0

0

0

0

Bits 0 to 7/BERT Bit Counter Bits 16 to 23 (BBC16 to BBC23).

Register Name:

BBC4

Register Description:

BERT Bit Count Register 4

Register Address:

E6h

Bit #

Name

Default

7

6

5

4

3

2

1

0

BBC31

BBC30

BBC29

BBC28

BBC27

BBC26

BBC25

BBC24

0

0

0

0

0

0

0

0

Bits 0 to 7/BERT Bit Counter Bits 24 to 31 (BBC24 to BBC31). BBC31 is the MSB of the 32-bit counter.

184 of 248

012103

Please contact telecom.support@dalsemi.com or search http://www.maxim-ic.com for updated

information.

Page 184
Image 184