Product Preview

 

 

 

 

 

 

 

 

DS21Q55

Register Name:

 

ESIBCR1

 

 

 

 

 

 

 

Register Description:

Extended System Information Bus Control Register 1

 

 

 

Register Address:

B0h

 

 

 

 

 

 

 

 

Bit #

7

6

5

4

3

2

 

1

0

 

Name

 

-

-

-

-

ESIBSEL2

ESIBSEL1

 

ESIBSEL0

ESIEN

 

Default

 

0

0

0

0

0

0

 

0

0

 

Bit 0/Extended System Information Bus Enable (ESIEN). 0 = disabled

1 = enabled

Bits 1 to 3/Output Data Bus Line Select (ESIBSEL0 to ESIBSEL2). These bits tell the device which data bus bit to output the ESIB data on when one of the ESIB information registers is accessed. Each member of the ESIB group must have a unique bit selected.

ESIBSEL2

ESIBSEL1

ESIBSEL0

BUS BIT DRIVEN

0

0

0

AD0

0

0

1

AD1

0

1

0

AD2

0

1

1

AD3

1

0

0

AD4

1

0

1

AD5

1

1

0

AD6

1

1

1

AD7

Bit 4/Unused, must be set to zero for proper operation.

Bit 5/Unused, must be set to zero for proper operation.

Bit 6/Unused, must be set to zero for proper operation.

Bit 7/Unused, must be set to zero for proper operation.