E1 ALARM CRITERIA Table 11-2

 

 

 

 

 

 

 

 

ALARM

SET CRITERIA

CLEAR CRITERIA

ITU

 

SPEC.

 

 

 

 

 

RLOS

An RLOS condition exists on power-

 

 

 

 

up prior to initial synchronization,

 

 

 

 

when a re-sync criteria has been met,

 

 

 

 

or when a manual re-sync has been

 

 

 

 

initiated via E1RCR1.0

 

 

 

RCL

255 or 2048 consecutive zeros

In 255-bit times, at least 32

G.775/G.962

 

 

received as determined by E1RCR2.0

ones are received

 

 

RRA

Bit 3 of nonalign frame set to one for

Bit 3 of nonalign frame set

O.162

 

 

three consecutive occasions

to zero for three consecutive

2.1.4

 

 

 

occasions

 

 

RUA1

Fewer than three zeros in two frames

More than two zeros in two

O.162

 

 

(512 bits)

frames (512 bits)

1.6.1.2

 

RDMA

Bit 6 of timeslot 16 in frame 0 has

 

 

 

 

been set for two consecutive

 

 

 

 

multiframes

 

 

 

V52LNK

Two out of three Sa7 bits are zero

 

G.965

58 of 248

012103