Product Preview

 

 

 

 

 

 

 

 

 

DS21Q55

Register Name:

E1TCR1

 

 

 

 

 

 

 

 

Register Description:

E1 Transmit Control Register 1

 

 

 

 

 

Register Address:

35h

 

 

 

 

 

 

 

 

Bit #

7

6

 

5

4

 

3

2

1

0

 

Name

TFPT

T16S

 

TUA1

TSiS

 

TSA1

THDB3

TG802

TCRC4

 

Default

0

0

 

0

0

 

0

0

0

0

 

Bit 0/Transmit CRC4 Enable (TCRC4). 0 = CRC4 disabled

1 = CRC4 enabled

Bit 1/Transmit G.802 Enable (TG802). See Functional Timing Diagrams for details. 0 = do not force TCHBLK high during bit 1 of timeslot 26

1 = force TCHBLK high during bit 1 of timeslot 26

Bit 2/Transmit HDB3 Enable (THDB3). 0 = HDB3 disabled

1 = HDB3 enabled

Bit 3/Transmit Signaling All Ones (TSA1). 0 = normal operation

1 = force timeslot 16 in every frame to all ones

Bit 4/Transmit International Bit Select (TSiS). 0 = sample Si bits at TSER pin

1 = source Si bits from TAF and TNAF registers (in this mode, E1TCR1.7 must be set to zero)

Bit 5/Transmit Unframed All Ones (TUA1). 0 = transmit data normally

1 = transmit an unframed all one’s code at TPOSO and TNEGO

Bit 6/Transmit Timeslot 16 Data Select (T16S). See Transmit Signaling for details

0 = timeslot 16 determined by the SSIEx registers and the THSCS function in the PCPR register 1 = source timeslot 16 from TS1 to TS16 registers

Bit 7/Transmit Timeslot 0 Pass Through (TFPT).

0 = FAS bits/Sa bits/Remote Alarm sourced internally from the TAF and TNAF registers 1 = FAS bits/Sa bits/Remote Alarm sourced from TSER

54 of 248

012103

Please contact telecom.support@dalsemi.com or search http://www.maxim-ic.com for updated

information.

Page 54