Product Preview

 

 

 

 

 

 

 

 

 

DS21Q55

9.3 E1 Information Registers

 

 

 

 

 

 

Register Name:

 

INFO3

 

 

 

 

 

 

 

 

Register Description:

Information Register 3

 

 

 

 

 

 

Register Address:

12h

 

 

 

 

 

 

 

 

Bit #

7

6

5

 

4

3

2

1

0

 

Name

 

-

-

-

 

-

-

CRCRC

FASRC

CASRC

 

Default

 

0

0

0

 

0

0

0

0

0

 

Bit 0/CAS Resync Criteria Met Event (CASRC). Set when two consecutive CAS MF alignment words are received in error.

Bit 1/FAS Resync Criteria Me t Event (FASRC. Set when three consecutive FAS words are received in error.

Bit 2/CRC Resync Criteria Met Event (CRCRC). Set when 915/1000 code words are received in error.

Register Name:

INFO7

Register Description:

Information Register 7 (Real Time)

Register Address:

30h

Bit #

Name

Default

7

6

5

4

3

2

1

0

CSC5

CSC4

CSC3

CSC2

CSC0

FASSA

CASSA

CRC4SA

0

0

0

0

0

0

0

0

Bit 0/CRC4 MF Sync Active (CRC4SA). Set while the synchronizer is searching for the CRC4 MF alignment word.

Bit 1/CAS MF Sync Active (CASSA). Set while the synchronizer is searching for the CAS MF alignment word.

Bit 2/FAS Sync Active (FASSA). Set while the synchronizer is searching for alignment at the FAS level.

Bit 3 to 7/CRC4 Sync Counter Bits (CSC0 and CSC2 to CSC4). The CRC4 sync counter increments each time the 8ms - CRC4 multiframe search times out. The counter is cleared when the framer has successfully obtained synchronization at the CRC4 level. The counter can also be cleared by disabling the CRC4 mode (E1RCR1.3 = 0). This counter is useful for determining the amount of time the framer has been searching for synchronization at the CRC4 level. ITU G.706 suggests that if synchronization at the CRC4 level cannot be obtained within 400ms, then the search should be abandoned and proper action taken. The CRC4 sync counter will rollover. CSC0 is the LSB of the 6-bit counter. (Note: The second LSB, CSC1, is not accessible. CSC1 is omitted to allow resolution to >400ms using 5 bits.)