Maxim DS21Q55 specifications E1TCR2, 36h, Bit 0/Automatic Remote Alarm Generation ARA = disabled

Models: DS21Q55

1 248
Download 248 pages 2 b
Page 55
Image 55

Product Preview

 

 

 

 

 

 

 

 

 

DS21Q55

Register Name:

E1TCR2

 

 

 

 

 

 

 

 

Register Description:

E1 Transmit Control Register 2

 

 

 

 

 

Register Address:

36h

 

 

 

 

 

 

 

 

Bit #

7

6

 

5

4

 

3

2

1

0

 

Name

Sa8S

Sa7S

 

Sa6S

Sa5S

 

Sa4S

AEBE

AAIS

ARA

 

Default

0

0

 

0

0

 

0

0

0

0

 

Bit 0/Automatic Remote Alarm Generation (ARA). 0 = disabled

1 = enabled

Bit 1/Automatic AIS Generation (AAIS). 0 = disabled

1 = enabled

Bit 2/Automatic E-Bit Enable (AEBE).

0 = E-bits not automatically set in the transmit direction 1 = E-bits automatically set in the transmit direction

Bit 3/Sa4 -Bit Select (Sa4S). Set to one to source the Sa4 bit from the TLINK pin; set to zero to not source the Sa4 bit. See Functional Timing Diagrams for details.

Bit 4/Sa5 -Bit Select (Sa5S). Set to one to source the Sa5 bit from the TLINK pin; set to zero to not source the Sa5 bit. See Functional Timing Diagrams for details.

Bit 5/Sa6 -Bit Select (Sa6S). Set to one to source the Sa6 bit from the TLINK pin; set to zero to not source the Sa6 bit. See Functional Timing Diagrams for details.

Bit 6/Sa7 -Bit Select (Sa7S). Set to one to source the Sa7 bit from the TLINK pin; set to zero to not source the Sa7 bit. See Functional Timing Diagrams for details.

Bit 7/Sa8 -Bit Select (Sa8S). Set to one to source the Sa8 bit from the TLINK pin; set to zero to not source the Sa8 bit. See Functional Timing Diagrams for details.

55 of 248

012103

Please contact telecom.support@dalsemi.com or search http://www.maxim-ic.com for updated

information.

Page 55
Image 55
Maxim DS21Q55 E1TCR2, 36h, Bit 0/Automatic Remote Alarm Generation ARA = disabled, Bit 2/Automatic E-Bit Enable Aebe