10 TROUBLESHOOTING
10.1.6 How to read the current operation status
This section explains how to read the current operation status of the Q series C24. When GX
REMARK
•The status of the switch settings by GX Developer can be checked by performing read operations as described in Section 10.1.5.
•Refer to Section 4.5 for the switch settings.
(1) Operation mode status storage area
The current operation status of the Q series C24 is stored into the following buffer memory areas.
1) Station No. storage area (address: 24FH)
b15 | to | b0 |
Buffer memory address 24FH | 0 to 31 | (Station No.) |
2) Communication protocol status storage area (addresses: 252H and 262H)
| b15 | to | b0 | |
Buffer memory address 252H | 1 to 7 |
| (Information on the CH1 side) | |
|
|
|
| (Information on the CH2 side) |
262H | 1 to 7 |
|
Mode number currently operating
Buffer memory address 253H 263H
3) Transmission status storage area (address : 253H, 263H)
b15 b14 b13 b12 b11 b10 | b9 | b8 | b7 | b6 | b5 | b4 | b3 | b2 | b1 | b0 | ||||||
0 | 0 | 0 | 0 | 1/0 | 1/0 | 1/0 | 1/0 | 1/0 | 1/0 | 1/0 | 1/0 | 1/0 | 1/0 | 1/0 | 1/0 (Information on the CH1 side) | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 | 0 | 0 | 0 | 1/0 | 1/0 | 1/0 | 1/0 | 1/0 | 1/0 | 1/0 | 1/0 | 1/0 | 1/0 | 1/0 | 1/0 (Information on the CH2 side) | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Communication rate setting | Operation setting |
| Data bit setting |
| Parity bit setting |
| Even/odd parity setting |
| Stop bit setting |
| Sum check code setting |
| Write during RUN setting |
| Setting modification allow/prohibit |
10 - 13 | 10 - 13 |