3 SPECIFICATIONS
Address |
|
|
|
|
| Initial | Applicable | Registration | Reference | ||||
Decimal (Hex) | Application |
|
|
| Name | protocol |
| allowed/not | |||||
|
|
| value |
| section | ||||||||
CH1 | CH2 |
|
|
|
|
| MC | Non |
| Bi | allowed | ||
|
|
|
|
|
|
|
| ||||||
|
|
| Transmission sequence status (For confirmation of MC protocol |
|
|
|
|
|
|
| |||
|
|
| communication status) |
|
|
|
|
|
|
|
| ||
|
|
| 0: Waiting for receiving command |
|
|
|
|
|
|
| |||
597 | 613 |
| 1: Receiving command |
|
| R | — |
|
|
| |||
| 2: Command reception complete |
|
|
| Section | ||||||||
(255H) | (265H) |
|
|
|
| ||||||||
| 3: Waiting to access PLC CPU |
|
|
|
|
|
| 8.6.4 | |||||
|
|
|
|
|
|
|
|
| |||||
|
|
| 4: Accessing PLC CPU |
|
|
|
|
|
|
| Section | ||
|
|
| 5: PLC CPU access complete |
|
|
|
|
|
| 10.1.4 | |||
|
|
| 6: Response message transmission | 0 |
|
|
|
| Not allowed |
| |||
598 | 614 |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| |||||
| 0 | : Normal completion |
| RW | — |
|
|
| |||||
(256H) | (266H) |
|
|
|
|
| |||||||
| 1 or more: Abnormal completion (error code) |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| ||||
599 | 615 | For confirmation | Data transmission result |
|
|
|
|
|
|
| Chapter 6 | ||
of communica- | 0 | : Normal completion |
|
|
|
|
|
| Chapter 7 | ||||
(257H) | (267H) |
|
|
|
|
|
| ||||||
|
| tion result | 1 or more: Abnormal completion (error code) |
|
| RW |
|
| Section | ||||
600 | 616 |
| Data reception result |
|
|
|
|
| 8.6.5 | ||||
|
|
|
|
|
|
|
| ||||||
| 0 | : Normal completion |
|
|
|
|
|
| Section | ||||
(258H) | (268H) |
|
|
|
|
|
|
| |||||
| 1 or more: Abnormal completion (error code) |
|
|
|
|
|
| 8.6.6 | |||||
|
|
|
|
|
|
|
|
| |||||
601 | 617 |
| System area |
|
|
|
|
|
| — |
| ||
(259H) | (269H) |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| ||
602 | 618 |
| MC protocol transmission error code |
|
|
|
|
|
| Section | |||
| (excludes A compatible 1C frame communication) |
| RW | — |
|
| |||||||
(25AH) | (26AH) |
|
|
|
| 8.6.4 | |||||||
| 0: No error | 1 or more: Transmission error code |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| ||||
|
|
| Receive user frame (nth) |
| 0 |
|
|
|
| Not allowed |
| ||
603 | 619 |
| 0 | : Not received |
|
| — | R |
| — |
| Section | |
(25BH) | (26BH) |
| 1 to 4: Combination of user frame No. designations for reception |
|
|
| 8.6.5 | ||||||
|
|
|
|
|
|
| |||||||
|
|
|
| message |
|
|
|
|
|
|
|
| |
604 to | 620 to |
|
|
|
|
|
|
|
|
|
|
|
|
607 | 1023 | Use prohibited | System area |
|
|
|
|
|
| — |
| ||
(25CH | (26CH to |
|
|
|
|
|
|
| |||||
to 25FH) | 3FFH) |
|
|
|
|
|
|
|
|
|
|
|
|
1024 | 2048 |
| Transmission data count designation |
|
|
|
|
|
|
| |||
(400H) | (800H) |
| 0: No designation | 1 or more: Number of send data |
|
|
|
|
|
|
| ||
1025 to | 2049 to |
| Transmission data designation |
|
|
|
|
|
| Chapter 6 | |||
1535 | 2559 |
|
|
|
|
|
|
|
|
|
|
| Chapter 7 |
(401H to | (801H to |
| Data to be sent to an external device |
|
|
|
|
|
| ||||
Transmission/rece |
|
|
|
|
|
| Section | ||||||
5FFH) | 9FFH) | 0 |
| RW |
| Not allowed | |||||||
1536 | 2560 | ive area | Receive data count (Number of data for which read is requested) |
|
| 8.4.5 | |||||||
|
|
|
|
|
| ||||||||
(600H) | (A00H) |
| 0: No receive data | 1 or more: Number of receive data |
|
|
|
|
|
| Section | ||
1537 to | 2561 to |
| Receive data |
|
|
|
|
|
|
| 8.4.7 | ||
2047 | 3071 |
|
|
|
|
|
|
|
|
|
|
|
|
(601H to | (A01H to |
| Data received from an external device |
|
|
|
|
|
|
| |||
7FFH) | BFFH) |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| ||
3072 to 6911 | For user | User free area (3840 words) |
| 0 |
| RW |
| Not allowed | — | ||||
(C00H to 1AFFH) |
| Determined by the user. |
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
| ||||
6912to 6952 |
| For registration No. 8001H |
|
|
|
|
|
|
|
|
| ||
(1B00H to 1B28H) |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| ||
6953 to 6993 |
| For registration No. 8002H |
|
|
|
|
|
|
|
|
| ||
(1B29H to 1B51H) |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| ||
6994 to 7034 |
| For registration No. 8003H | The user registration area has the following combined uses, with |
|
| ||||||||
(1B52H to 1B7AH) |
|
|
| ||||||||||
7035 to 7075 |
| For registration No. 8004H | data written by the user according to the purpose of use by the |
|
|
| |||||||
(1B7BH to 1BA3H) |
| TO instruction, etc. |
|
|
|
|
|
|
| ||||
7076 to 7116 |
| For registration No. 8005H | See each explanation item concerning the configuration of each |
|
| ||||||||
(1BA4H to 1BCCH) |
|
|
| ||||||||||
7117 to 7157 |
| For registration No. 8006H | area, the data written, etc. |
|
|
|
|
|
|
| |||
(1BCDH to 1BF5H) |
| (1) | If data communications is being carried out by user |
|
|
|
|
| |||||
7158 to 7198 |
| For registration No. 8007H |
| registration frame. |
|
|
|
|
|
| Refer to left | ||
(1BF6H to 1C1EH) |
|
| • User registration frame (User’s Manual (Application), |
| Not allowed | ||||||||
7199 to 7239 |
| For registration No. 8008H |
|
| description | ||||||||
(1C1FH to 1C47H) |
|
| Chapter 9) |
|
|
|
|
|
|
| |||
7240 to 7280 |
| For registration No. 8009H | (2) | If data communications is being carried out by the modem |
|
|
| ||||||
(1C48H to 1C70H) |
|
|
|
| |||||||||
|
|
|
|
|
| function. |
|
|
|
|
|
|
|
7281 to 7321 |
| For registration No. 800AH |
|
|
|
|
|
|
|
| |||
|
| • Initialization Data (User’s Manual (Application) Section |
|
|
| ||||||||
(1C71H to 1C99H) |
|
|
|
|
| ||||||||
7322 to 7362 |
| For registration No. 800BH |
| 3.4.3) |
|
|
|
|
|
|
| ||
(1C9AH to 1CC2H) |
|
| • Connection Data (User’s Manual (Application) Section |
|
|
| |||||||
7363 to 7403 |
| For registration No. 800CH |
|
|
|
| |||||||
|
| 3.4.4) |
|
|
|
|
|
|
| ||||
(1CC3H to 1CEBH) |
|
|
|
|
|
|
|
|
| ||||
7404 to 7444 |
| For registration No. 800DH |
|
|
|
|
|
|
|
|
| ||
(1CECH to 1D14H) |
|
|
|
|
|
|
|
|
|
| |||
7445 to 7485 |
| For registration No. 800EH |
|
|
|
|
|
|
|
|
| ||
(1D15H to 1D3DH) |
|
|
|
|
|
|
|
|
|
|
3 - 25 | 3 - 25 |