APPENDIX

MELSEC-Q

Function

Q series C24

QC24N

QC24

UC24

C24-S8

Accessing other stations with link dedicated instructions

 

(via QC24 (N))

 

 

Interrupt processing

Non procedure protocol

 

 

 

 

 

(at data reception)

Bidirectional protocol

 

 

 

 

 

Communication via public lines using modem function

 

 

 

 

 

Communication using the PLC CPU monitoring function

 

 

 

 

 

Auto refresh directed to the PLC CPU

 

 

 

 

 

Transmission control

DC code control

 

 

 

 

 

DTR/DSR signal control

 

 

 

 

 

 

 

 

 

 

 

Half-duplex communication control

 

 

 

 

 

 

Mode switching

 

 

 

 

 

 

Independent operation of two

Setting the same protocol

 

 

 

 

 

interfaces

Setting different protocols

 

 

 

 

 

Linked operation of two interfaces

 

 

 

 

 

 

Registering initial setting values of the buffer memory

(Flash ROM)

(EEPROM)

 

 

Registering user frame

 

 

 

 

 

 

 

 

 

Connection forms with external

1:1, 1:n

 

 

 

 

 

devices

m:n

 

 

 

 

 

I/O signal transmission/receive by multi drop link function

 

 

 

 

 

Connection of GX Developer

 

 

 

 

 

 

Communication data monitoring

 

 

 

 

 

 

Registering and monitoring of setting values by the utility package

 

 

 

 

 

 

 

QCPU

QnACPU

ACPU

ACPU

 

 

AnACPU

AnACPU

PLC that can be mounted

 

MELSECNET/H

MELSECNET/10,

 

AnUCPU

AnUCPU

 

 

remote I/O station

Remote I/O station

 

 

QnACPU

QnACPU

Data transmission rate (bps)

 

230400 maximum

115200

19200

19200

19200

 

( 6)

maximum maximum maximum maximum

 

 

: Function exists/possible : Function exists/possible (specification is different depends on the function version (see Appendix 1) : No function/impossible

1

Access is possible only within the range of an AnACPU device.

 

 

2

A multiple block batch read/write function can be used for the local station QCPU to which the Q series

 

C24 is mounted and the next CPU module, which will be another station, via MELSECNET/H,

 

MELSECNET/10.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function

 

PLC CPU

 

 

 

 

QCPU

QnACPU

Q2AS(H)

Q4AR

 

 

 

 

 

 

 

Multiple block batch read/write

(All allowed)

(9707B or later products)

(All allowed)

 

This function is added to modules showing 9707B or later in the package indication and the DATE column of the rating plate.

3

Access to other stations cannot be performed via data link system (MELSECNET(II), MELSECNET/B).

4

Transmission is only possible using the printer function.

 

5

When the Q series C24 is used, it is possible to read/write a maximum of 960 words (in case of QC24(N), it

 

is possible to read/write a maximum of 480 words.)

 

6

230400 bps can be used via CH1 of QJ71C24N (-R2/R4) only.

 

 

The maximum transmission speed of QJ71C24 (-R2) is 115200 bps.

 

App. - 7

App. - 7