3 SPECIFICATIONS

MELSEC-Q

Address

 

 

 

 

 

Initial

 

Applicable

Registration

Reference

 

Decimal (Hex)

Application

 

 

Name

 

protocol

allowed/not

 

 

 

value

 

section

 

CH1

CH2

 

 

 

 

 

MC

Non

Bi

allowed

 

 

 

 

 

 

 

 

 

7486 to 7526

 

For registration No. 800FH

 

 

 

 

 

 

 

 

 

 

 

(1D3EH to 1D66H)

 

 

 

 

 

 

 

 

 

 

 

 

7527 to 7567

 

For registration No. 8010H

 

 

 

 

 

 

 

 

 

 

 

(1D67H to 1D8FH)

 

 

 

 

 

 

 

 

 

 

 

 

7568 to 7608

 

For registration No. 8011H

 

 

 

 

 

 

 

 

 

 

 

(1D90H to 1DB8H)

 

 

 

 

 

 

 

 

 

 

 

 

7609 to 7649

 

For registration No. 8012H

 

 

 

 

 

 

 

 

 

 

 

(1DB9H to 1DE1H)

 

The user registration area has the following combined uses, with

 

 

 

7650 to 7690

 

For registration No. 8013H

data written by the user according to the purpose of use by the

 

 

 

(1DE2H to 1E0AH)

 

 

 

 

7691 to 7731

 

For registration No. 8014H

TO instruction, etc.

 

 

 

 

 

 

 

 

(1E0BH to 1E33H)

 

See each explanation item concerning the configuration of each

 

 

 

7732 to 7772

 

For registration No. 8015H

area, the data written, etc.

 

 

 

 

 

 

 

 

(1E34H to 1E5CH)

 

 

 

 

 

 

 

 

 

7773 to 7813

 

For registration No. 8016H

(1)

If data communications is being carried out by user

 

 

 

 

 

(1E5DH to 1E85H)

 

 

 

registration frame.

 

 

 

 

 

 

Refer to left

7814 to 7854

 

 

 

 

 

 

 

 

Not allowed

 

For registration No. 8017H

 

User registration frame (User’s Manual (Application),

(1E86H to 1EAEH)

 

 

description

7855 to 7895

 

For registration No. 8018H

 

 

Chapter 9)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1EAFH to 1DE7H)

 

(2)

If data communications is being carried out by the modem

 

 

 

7896 to 7936

 

For registration No. 8019H

 

 

 

 

 

function.

 

 

 

 

 

 

 

 

(1ED8H to 1F00H)

 

 

 

 

 

 

 

 

 

 

7937 to 7977

 

For registration No. 801AH

 

Initialization Data (User’s Manual (Application)

Section

 

 

 

(1F01H to 1F29H)

 

 

 

3.4.3)

 

 

 

 

 

 

 

 

7978 to 8018

 

For registration No. 801BH

 

 

 

 

 

 

 

 

 

 

 

 

Connection Data (User’s Manual (Application)

Section

 

 

 

(1F2AH to 1F52H)

 

 

 

 

 

8019 to 8059

 

For registration No. 801CH

 

 

3.4.4)

 

 

 

 

 

 

 

 

(1F53H to 1F7BH)

 

 

 

 

 

 

 

 

 

 

 

 

8060 to 8100

 

For registration No. 801DH

 

 

 

 

 

 

 

 

 

 

 

(1F7CH to 1FA4H)

 

 

 

 

 

 

 

 

 

 

 

 

8101 to 8141

 

For registration No. 801EH

 

 

 

 

 

 

 

 

 

 

 

(1FA5H to 1FCDH)

 

 

 

 

 

 

 

 

 

 

 

 

8142 to 8182

 

For registration No. 801FH

 

 

 

 

 

 

 

 

 

 

 

(1FCEH to 1FF6H)

 

 

 

 

 

 

 

 

 

 

 

 

8183 to 8191

Use prohibited

System area

 

 

 

 

 

 

 

 

 

(1FF7H to1FFFH)

 

 

 

 

 

 

 

 

 

 

 

 

 

8192

System

Flash ROM write allow/prohibit designation

0

 

 

RW

Not allowed

Section

(2000H)

designation

0: Write prohibited

 

1: Write allowed

 

 

8.4.12

 

 

 

 

 

 

 

 

 

 

 

 

Callback function designation

 

 

 

 

 

 

 

 

 

 

 

 

 

0H: Auto

 

 

 

 

 

 

 

 

 

 

 

 

 

1H: Callback connection (during fixed)·····························(Setting 4)

 

 

 

 

 

 

 

 

 

 

 

3H: Callback connection (during designated number)·····(Setting 5)

 

 

 

 

 

 

Section

8193

 

7H: Callback connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8.4.4

 

 

(during max. designated number is 10)·····················(Setting 6)

0

 

 

 

 

 

 

(2001H)

 

 

 

 

 

 

 

For callback

9H: Auto/Callback connection (during fixed)·····················(Setting 1)

 

RW

Allowed

Chapter 3 of

 

 

function

BH: Auto/Callback connection

 

 

 

User’s

 

 

 

 

 

 

 

 

 

 

 

 

 

(during designated number)·······································(Setting 2)

 

 

 

 

 

 

Manual

 

 

 

FH: Auto/Callback connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Application)

 

 

 

(during max. designated number is 10)·····················(Setting 3)

 

 

 

 

 

 

8194

 

Callback denial notification accumulated count designation

 

 

 

 

 

 

 

 

 

0H: Not specified

 

 

1

 

 

 

 

 

 

 

(2002H)

 

 

 

 

 

 

 

 

 

 

 

1H to FFFFH: Notification accumulated number count

 

 

 

 

 

 

 

 

8195 to 8198

Use prohibited

System area

 

 

 

 

 

 

 

 

 

(2003H to 2006H)

 

 

 

 

 

 

 

 

 

8199

 

Auto modem initialization designation

0

 

 

 

 

 

 

 

(2007H)

 

0: Do not auto initialize 1: Auto initialize

 

 

 

 

 

Section

 

 

 

 

 

 

 

8200

 

Modem initialization time DR (DSR) signal valid/invalid designation

 

 

 

 

 

 

For designation

1

 

 

 

 

 

8.4.4

 

(2008H)

0: Do not ignore DR signal.

 

1: Ignore DR signal.

 

 

RW

Allowed

Chapter 3

 

 

 

 

 

 

8201

of modem

Complete signal handling for modem function designation

 

 

 

 

function -2

0: Do not turn on/off X13 to X16.

1

 

 

 

 

 

of User's

 

(2009H)

 

 

 

 

 

Manual

 

 

1: Turn on/off X13 to X16.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Application)

 

8202

 

Wait time of notification designation

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(200AH)

 

0000H to FFFFH: Wait time (unit: s)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8203

Use prohibited

System area

 

 

 

 

 

 

 

 

 

(200BH)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8204

 

Remote password mismatch notification count designation

0

 

 

 

 

 

Section 5.1.5

 

0H: No designation

 

 

 

 

 

 

 

(200CH)

 

 

 

 

 

 

 

 

For remote

1H to FFFFH: Notification times

 

 

 

 

 

 

 

 

Section 8.4.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chapter 3 of

 

 

password

Remote password mismatch notification accumulated count

 

RW

Allowed

8205

 

User's

function

designation

 

 

1

 

 

 

 

 

Manual

(200DH)

 

0H: No designation

 

 

 

 

 

 

 

(Application)

 

 

 

 

 

 

 

 

 

 

 

 

1H to FFFFH: Cumulative times of notification

 

 

 

 

 

 

 

 

3 - 26