3 SPECIFICATIONS
Address |
|
|
|
| Initial | Applicable | Registration | Reference | ||||||||
Decimal (Hex) | Application |
|
| Name | protocol |
|
| allowed/not | ||||||||
|
| value |
|
| section | |||||||||||
CH1 | CH2 |
|
|
|
| MC | Non |
| Bi | allowed | ||||||
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
| Transmission pointer designation (for condition |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| agreement transmission) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 to 100: Output head point (send from nth) |
|
|
|
|
|
|
|
|
|
|
|
8422 | 8678 |
|
|
| Send the user frames designated in the following |
|
|
|
|
|
|
|
|
|
|
|
(20E6H) | (21E6H) |
|
|
| transmission frame No. designation areas from the |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| designated pointer position. |
|
|
|
|
|
|
|
|
|
|
|
|
| For designation | CPU | (address: CH1 side = BAH to 11DH, CH2 side = |
|
|
|
|
|
|
|
|
|
| Chapter 2 | |
|
| of PLC CPU | abnormal | 15AH to 1BDH) | 0 |
| R |
|
| — |
| Allowed |
| of User's | ||
|
| monitoring | monitoring | Output count designation (for condition agreement |
|
|
|
|
| Manual | ||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
8423 | 8679 | function | designation | transmission) |
|
|
|
|
|
|
|
|
|
| (Application) | |
(20E7H) | (21E7H) |
|
|
| 1 to 100: Output count (designate the number of |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| frame transmissions) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Data No. for connection designation (for condition |
|
|
|
|
|
|
|
|
|
|
|
8424 | 8680 |
|
|
| agreement transmission and notification) |
|
|
|
|
|
|
|
|
|
|
|
(20E8H) | (21E8H) |
|
|
| 0BB8H to 0BD5H, 8001H to 801FH: Data No. for |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| connection |
|
|
|
|
|
|
|
|
|
|
|
8425 to | 8681 to |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8447 | 8703 | Use prohibited | System area |
|
|
|
|
|
|
|
| — |
| |||
(20E9H to | (21E9H to |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
20FFH) | 21FFH) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8448 (2100H) | Use Prohibited | System area |
|
|
|
|
|
|
|
| — |
| ||||
8449 (2101H) |
| Data No. for callback designation 1 |
|
|
|
|
|
|
|
|
|
|
| |||
| 0BB8H to 0BD5H, 8001H to 801FH: Data number for callback. |
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
8450 (2102H) |
| Data No. for callback designation 2 |
|
|
|
|
|
|
|
|
|
| Section | |||
8451 (2103H) |
| Data No. for callback designation 3 |
|
|
|
|
|
|
|
|
|
| ||||
8452 (2104H) | For callback | Data No. for callback designation 4 |
|
|
|
|
|
|
|
|
|
| 8.4.4 | |||
0 |
| RW | — |
|
|
|
| Chapter 3 of | ||||||||
8453 (2105H) | Data No. for callback designation 5 |
|
|
| Allowed |
| ||||||||||
function |
|
|
|
| User’s | |||||||||||
8454 (2106H) | Data No. for callback designation 6 |
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| Manual | |||||
8455 (2107H) |
| Data No. for callback designation 7 |
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| (Application) | |||||
8456 (2108H) |
| Data No. for callback designation 8 |
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
8457 (2109H) |
| Data No. for callback designation 9 |
|
|
|
|
|
|
|
|
|
|
| |||
8458 (210AH) |
| Data No. for callback designation 10 |
|
|
|
|
|
|
|
|
|
|
| |||
8704 to | 8960 to |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8707 | 8963 | Use prohibited | System area |
|
|
|
|
|
|
|
| — |
| |||
(2200Hto | (2300Hto |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2203H) | 2303H) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| PLC CPU monitoring function operation status |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| 0: Not executed (waiting for registration of PLC CPU monitoring) |
|
|
|
|
|
|
|
|
|
|
| ||
8708 | 8964 |
| 1: Wait for PLC CPU monitoring time |
|
|
|
|
|
|
|
|
|
|
| ||
(2204H) | (2304H) |
|
| (waiting to access PLC CPU) |
|
|
|
|
|
|
|
|
|
|
| |
|
|
| 2: Accessing PLC CPU |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| 3: Sending monitoring results |
|
|
|
|
|
|
|
|
|
|
| ||
8709 | 8965 |
| PLC CPU monitoring function execution result (current) |
|
|
|
|
|
|
|
|
|
|
| ||
| 0: Normal completion |
|
|
|
|
|
|
|
|
|
| Chapter 2 | ||||
(2205H) | (2305H) | PLC CPU |
|
|
|
|
|
|
|
|
|
| ||||
1 or more: Abnormal completion (error code) |
|
|
|
|
|
|
|
|
|
| of User's | |||||
|
| monitoring | 0 |
| R |
|
| — |
| Not allowed |
| |||||
|
| PLC CPU monitoring function number of transmission |
|
|
|
|
| Manual | ||||||||
8710 | 8966 | function |
|
|
|
|
|
|
|
|
|
| ||||
0: Not executed |
|
|
|
|
|
|
|
|
|
| (Application) | |||||
(2206H) | (2306H) |
|
|
|
|
|
|
|
|
|
|
| ||||
| 1 or more: Number of transmissions |
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| Monitoring condition arrival block No. |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| 0 | : The monitoring condition is not enabled for any block |
|
|
|
|
|
|
|
|
|
|
| |
8711 | 8967 |
| 1 to 10: Registration order of word/bit block (nth) |
|
|
|
|
|
|
|
|
|
|
| ||
(2207H) | (2307H) |
| 4096 : CPU abnormal monitoring block |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| The latest block No. for which monitoring condition is enabled is |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| stored. |
|
|
|
|
|
|
|
|
|
|
|
|
8712 to | 8968 to |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8954 | 9215 | Use prohibited | System area |
|
|
|
|
|
|
|
| — |
| |||
(2208Hto | (2308Hto |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
22FAH) | 23FFH) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 - 29 | 3 - 29 |