CDM-Qx Satellite Modem

Revision 5

Front Panel Operation

MN/CDMQx.IOM

(Config„ODU„LNB„Power-On/Off) – LNB POWER- ON/OFF

If Power-On/Offis selected, the following sub-menu is displayed:

LNB

Power:

(◄ ► ENT)

On

Off

Select On or Off, using the ◄ ► arrow keys, then press ENT.

(Config„ODU„LNB„10MHz) - LNB 10MHz

If 10MHz is selected, the following sub-menu is displayed:

LNB

10MHz Reference:

(◄ ► ENT)

On

Off

Select On or Off, using the ◄ ► arrow keys, then press ENT.

(Config„ODU„LNB„Alarm) - LNB ALARM

If Alarm is selected, the following sub-menu is displayed:

Set LNB Current Alarm:

Upper Lower

(◄ ► ENT)

Select Upper or Lower, using the ◄ ► arrow keys, then press ENT.

If Upper is selected, the following sub-menu is displayed:

LNB Current Alarm Upper

ENT)

Limit: 200mA

(◄ ► ▲

Edit the LNB Current Alarm Upper limit. This is accomplished by selecting the digit to be edited, using the WXarrow keys. The value of the digit is then changed using the STarrow keys. The user should then press ENT. The range of current is from 50 to 600 mA.