Mocomtech CDM-QX operation manual Bytes, Uid?

Models: CDM-QX

1 258
Download 258 pages 16.72 Kb
Page 221
Image 221

CDM-Qx Satellite Modem

Revision 4

Remote Control

MN/CDMQx.IOM

Parameter

Type

Command

(Instruction

Code and qualifier)

Arguments for

Command or Response to Query

Description of Arguments

Response

to

Command

(Target to

Controller)

Query

(Instruction

Code and Qualifier)

Response to query (Target to Controller)

Unit ID

N/A

7 bytes

Query only

Unit returns information concerning the base unit identification and the option field in the form: abcdefg

a=Redundancy option: 0=None, 1=1:1 mode, 2=1:2 mode, 3=1:3 mode.

Note: if a=3, capable of supporting also1:2 and 1:1. If a=2, capable of supporting 1:1 as well.

b=CnC First Instance rate option: 0=None,

1=128 Kbps to 512Kbps, 2=128Kbps to 1Mbps, 3=128Kbps to 2.5Mbps, 4=128Kbps to 5Mbps, 5=128Kbps to 10Mbps, 6=128Kbps to 20Mbps.

c=CnC Second Instance rate option: 0=None,

1=128 Kbps to 512Kbps, 2=128Kbps to 1Mbps, 3=128Kbps to 2.5Mbps, 4=128Kbps to 5Mbps, 5=128Kbps to 10Mbps, 6=128Kbps to 20Mbps.

d=Unit Type 0=70/140MHz unit

1=L-Band unit with one 24V power supply 2=L-Band unit with one 48V power supply 3=L-Band unit with two 24V power supplies 4=L-Band unit with two 48V power supplies

e=D&I++ option 0=None

1=One modem only 2=Two modems

f=spare

g=spare

N/A

UID?

UID=abcdefg (see description of arguments)

C-31