CDM-Qx Satellite Modem

Revision 5

Front Panel Operation

MN/CDMQx.IOM

(Config„Rx„Misc„EbNo) - Eb/No ALARM

Eb/No Alarm Point:

02.0 dB

(◄ ►,▲ ▼,ENT)

Edit the Eb/No alarm point. This is accomplished by selecting the digit to be edited, using the ◄ ► arrow keys. The value of the digit is then changed using the STarrow keys. The user should then press ENT.

The range of values is from 2.0 to 16.0 dB. The user may select a value here, and if the Eb/No falls below this value, a receive traffic fault will be generated.

(Config„Rx„Misc„Rxα) – RX Roll-Off (α) factor

Rx Roll-off: 20% 35%

(◄ ►, ENT)

Select 20% or 35%, using the ◄ ► arrow keys, then press ENT. The default is 35%.

(Config„Rx„CnC) – CARRIER-IN-CARRIER

Carrier-in-Carrier (CnC):

Mode FrqOffs SrchDelay ReAcq

Select Mode, FrqOffs, SrchDelay, or ReAcq using the WXarrow keys, then press ENT. The user will then be taken to a further sub-menu. Each of these choices is described briefly in the table below:

Mode

(Mode of Operation) This sub-menu permits the user to select the mode of

 

operation for the CnC.

FrqOffs

(Frequency Offset) This sub-menu permits the user to adjust the frequency

 

offset for the CnC.

SrchDelay

(Search Delay) This sub-menu permits the user to configure the search

 

delay parameters for the CnC.

ReAcq

(ReAcquisition Time) This permits the user to set the re-acquisition time in

 

seconds when the desired carrier is lost.

5–31

Page 85
Image 85
Mocomtech CDM-QX operation manual Config„Rx„Misc„EbNo Eb/No Alarm, Config„Rx„Misc„Rxα RX Roll-Off α factor