Mocomtech CDM-QX operation manual Parameter Command Instruction Type Code Qualifier

Models: CDM-QX

1 258
Download 258 pages 16.72 Kb
Page 237
Image 237

CDM-Qx Satellite Modem

Revision 4

Remote Control

 

MN/CDMQx.IOM

C.5.8

Built-in BERT commands (BER Tester)

 

 

Parameter

 

Command

 

 

(Instruction

 

Type

 

Code and

 

 

 

Qualifier)

 

 

 

 

 

Built-in BERT

 

BST=

 

state (applies to

 

 

 

card-by-card

 

 

 

basis)

 

 

 

 

 

 

 

BERT Config

 

BCP=

 

Pattern state

 

 

 

(applies to card-

 

 

 

by-card basis)

 

 

BERT Restart

BRM=

Monitor (applies

 

to Rx card)

 

 

 

BERT 10E-3

BKE=

Error Insert

 

(applies to Tx

 

card)

 

Arguments

for

Command or Response to Query

1 byte, value of 0 and 1

1 byte

1byte, value of 1 only

1 byte, value of 0, 1

 

Description of arguments

 

 

Response to

 

 

Query

 

 

Response to query

 

 

 

 

Command

 

 

(Instruction

 

 

 

 

 

 

 

 

 

 

(Target to

 

 

 

 

 

(Target to

 

 

Code and

 

 

 

 

 

 

 

 

 

 

 

Controller)

 

 

 

 

 

Controller)

 

 

Qualifier)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command or Query

 

BST=

 

 

BST?

 

 

BST=x

 

State of built-in tester (BST), where:

 

BST?

 

 

 

 

(see description of

 

0=Off

 

BST*

 

 

 

 

arguments)

 

1=On

 

BST#

 

 

 

 

 

 

 

 

 

 

BST$

 

 

 

 

 

 

 

 

 

 

BST^

 

 

 

 

 

 

 

Command or Query

 

 

BCP=

 

 

BCP?

 

 

BCP=x

 

Syntax: BCP=x, where x=BERT pattern

 

 

BCP?

 

 

 

 

 

(see description of

 

BERT Pattern:

 

 

BCP*

 

 

 

 

 

arguments)

 

0

= space

 

 

BCP#

 

 

 

 

 

 

 

1

= mark

 

 

BCP$

 

 

 

 

 

 

 

2

= 1:1

 

 

BCP^

 

 

 

 

 

 

 

3

= 1:3

 

 

 

 

 

 

 

 

 

 

4

= 63

 

 

 

 

 

 

 

 

 

 

5

= 511

 

 

 

 

 

 

 

 

 

 

6

= 2047 (default)

 

 

 

 

 

 

 

 

 

 

7

= 2047R (or 2047 Alternate)

 

 

 

 

 

 

 

 

 

 

8

= Mil 188

 

 

 

 

 

 

 

 

 

 

9

= 2^15-1

 

 

 

 

 

 

 

 

 

 

A = 2^20-1

 

 

 

 

 

 

 

 

 

 

B = 2^23-1

 

 

 

 

 

 

 

 

 

 

Command only.

 

BRM=

 

 

N/A

 

N/A

 

Restarts or resets the BERT monitor.

 

BRM?

 

 

 

 

 

 

 

 

 

 

BRM#

 

 

 

 

 

 

 

Example: BRM=1

 

BRM$

 

 

 

 

 

 

 

 

 

 

BRM^

 

 

 

 

 

 

 

 

 

 

BRM@

 

 

 

 

 

 

 

Command or Query.

 

 

BKE=

 

 

BKE?

 

 

BKE=x

 

Inserts 10E-3 BER.

 

 

BKE?

 

 

 

 

 

(see description of

 

0

= Off

 

 

BKE#

 

 

 

 

 

arguments)

 

1

= On

 

 

BKE$

 

 

 

 

 

 

 

 

 

 

 

BKE^

 

 

 

 

 

 

 

Example: BKE=1

 

 

BKE@

 

 

 

 

 

 

 

C-47

Page 237
Image 237
Mocomtech CDM-QX operation manual Parameter Command Instruction Type Code Qualifier