CDM-Qx Satellite Modem

Revision 5

Front Panel Operation

MN/CDMQx.IOM

5.6.4.4(Info„Buffer) - BUFFER INFORMATION

Buffer: Enabled (Tx=Rx) (ENT)

This displays if the buffer is enabled or disabled, shows the exact clocking mode (TX=RX, or TX<> RX), and the buffer size. Pressing ENT takes the user back to the previous menu.

5.6.4.5(Info„Frame) – FRAMING AND EDMAC INFORMATION

Examples:

Framing: AUPC-Only, D&I++ (ENT or CLR)

Framing:AUPC-Only,EDMAC2 (ENT or CLR)

Framing: AUPC+EDMAC2

Master,0240

(ENT or CLR)

 

Framing: AUPC+EDMAC

Slave, 0241

(ENT or CLR)

This screen shows EDMAC mode, and shows if the unit is an EDMAC MASTER or SLAVE, with the appropriate address. Pressing ENT or CLR takes the user back to the previous menu.

5.6.4.6(Info„Interface) – INTERFACE INFORMATION

This screen shows details of the electrical interface type of the main data port. If RS422, V.35 or RS232 is selected, the menu will also indicate the operation of RTS/CTS. Pressing ENT or CLR takes the user back to the previous menu.

Example:

 

 

 

 

 

Interface: RS422

(ENT)

 

RTS/CTS Loop, No Action

 

5–69

Page 123
Image 123
Mocomtech CDM-QX Info„Buffer Buffer Information, Info„Frame Framing and Edmac Information, Buffer Enabled Tx=Rx ENT