Mocomtech CDM-QX operation manual Rne=, CC is Fault Code numbers, as in FLT? Or Infor Code, which

Models: CDM-QX

1 258
Download 258 pages 16.72 Kb
Page 224
Image 224

 

CDM-Qx Satellite Modem

 

 

 

 

 

 

 

Revision 4

 

 

 

 

 

 

 

 

Remote Control

 

 

 

 

 

 

MN/CDMQx.IOM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command

 

 

Arguments for

 

 

 

 

 

 

 

Response

 

 

Query

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to

 

 

 

 

Response to query

 

 

Parameter

 

 

(Instruction

 

 

Command or

 

 

Description of Arguments

 

 

 

 

(Instruction

 

 

 

 

 

 

 

 

 

 

 

 

Command

 

 

 

 

(Target to

 

 

Type

 

 

Code and

 

 

Response to

 

 

 

 

 

 

 

 

 

Code and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Target to

 

 

 

 

Controller)

 

 

 

 

 

qualifier)

 

 

Query

 

 

 

 

 

 

 

 

 

Qualifier)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controller)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of

 

 

N/A

 

3 bytes

 

 

Query only

 

 

 

 

N/A

 

 

NUE?

 

NUE=xxx

 

 

Unread Stored

 

 

 

 

 

 

 

 

Unit returns the number of stored Events, which remain

 

 

 

 

(see description of

 

 

Events

 

 

 

 

 

 

 

 

Unread, in the form of xxx.

 

 

 

 

 

 

 

 

 

arguments)

 

 

 

 

 

 

 

 

 

 

 

Note: This means unread over the remote control.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example: NUE=126

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Retrieve next 5

 

 

N/A

80 bytes

 

 

Query only

 

 

 

 

N/A

 

 

RNE?

 

 

RNE=

 

 

unread stored

 

 

 

 

 

 

 

 

Unit returns the oldest 5 Stored Events, which have not

 

 

 

 

 

{CR}ABCCddmmyyhh

 

 

Events

 

 

 

 

 

 

 

 

yet been read over the remote control. Reply format:

 

 

 

 

 

mmss{CR}ABCCddm

 

 

 

 

 

 

 

 

 

 

 

{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-

 

 

 

 

 

 

 

 

myyhhmmss{CR}ABC

 

 

 

 

 

 

 

 

 

 

 

body{CR}Sub-body{CR},

where

Sub-body

=

 

 

 

 

 

 

 

Cddmmyyhhmmss

 

 

 

 

 

 

 

 

 

 

 

ABCCddmmyyhhmmss,

 

 

 

 

 

 

 

 

 

 

{CR}ABCCddmmyyhh

 

 

 

 

 

 

 

 

 

 

 

A being the fault/clear indicator

 

 

 

 

 

 

 

 

 

 

mmss{CR}ABCCddm

 

 

 

 

 

 

 

 

 

 

 

F=Fault

 

 

 

 

 

 

 

 

 

 

myyhhmmss

 

 

 

 

 

 

 

 

 

 

 

C=Clear

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I =Info

 

 

 

 

 

 

 

 

 

 

(see description of

 

 

 

 

 

 

 

 

 

 

 

B being the fault type where:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

arguments)

 

 

 

 

 

 

 

 

 

 

 

1=Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2=RX Traffic on slot#1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3=RX Traffic on slot#2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4=RX Traffic on slot#3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5=RX Traffic on slot#4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6=TX Traffic on slot#1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7=TX Traffic on slot#2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8=TX Traffic on slot#3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9=TX Traffic on slot#4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A=ODU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B=Power ON/OFF, or log cleared

 

 

 

 

 

 

 

 

 

 

 

CCis Fault Code numbers, as in FLT? Or Infor Code, which

is:

0=Power Off 1=Power On 2=Log Cleared 3=Global Config Change 4=Redundancy Config Change

If there are less than 5 events to be retrieved, the remaining positions are padded with zeros.

If there are no new events, the response is RNE*.