CDM-Qx Satellite Modem

Revision 5

Front Panel Operation

MN/CDMQx.IOM

On most menu screens, the user will observe a flashing solid block cursor, which blinks at a once-per-second rate. This indicates the currently selected item, digit, or field. Where this solid block cursor would obscure the item being edited (for example, a numeric field) the cursor will automatically change to an underline cursor.

If the user were to display the same screen for weeks at a time, the display could become ‘burnt’ with this image. To prevent this, the unit has a ‘screen saver’ feature that will activate after 1 hour. The top line of the display will show the Circuit ID (which can be entered by the user) and the bottom line will show the circuit Eb/No value (if there is a demod and it is locked) followed by ‘Press any key....’. The message moves from right to

left across the screen, then wraps around. If there are multiple circuits, their messages and Eb/No’s will be displayed sequentially. Pressing any key will restore the previous screen. The behavior of the front panel LEDs is described below in Table 5-1.

 

 

 

 

 

 

 

Table 5-1. Front Panel LED Indicators

 

 

 

 

 

 

 

 

 

 

 

LED

 

 

Color

 

 

Condition

 

 

Unit

 

 

Red

 

 

A Unit Fault exists (Example: PSU fault)

 

 

 

 

Green

 

 

No Unit Faults

 

 

Status

 

 

 

 

 

 

 

 

 

 

 

Note: Unit fault does not include Tx or Rx fault.

 

 

 

 

 

 

 

 

 

 

Transmit

 

 

Green

 

 

No Tx Traffic Faults

 

 

 

 

Off

 

A Tx Traffic fault exists or the Tx Carrier is in OFF state

 

 

Traffic

 

 

 

 

 

 

 

 

 

 

Note: This LED corresponds to the selected slot, example <TX>.

 

 

 

 

 

 

 

 

 

 

Receive

 

 

Green

 

 

No Rx Traffic Faults (demod and Viterbi decoder are locked, everything is OK)

 

 

 

 

Off

 

 

An Rx Traffic fault exists (the demod may still be OK – check the fault status of the

 

 

Traffic

 

 

 

 

unit from the Monitor menu).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: This LED corresponds to the selected slot, example <RX>.

 

 

 

 

 

Green

 

 

The Unit is On Line, and carrying traffic

 

 

Online

 

 

Off

 

 

The Unit is Off Line (standby) - forced by externally connected 1:1 or 1:N

 

 

 

 

 

 

redundancy system

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: This LED corresponds to the selected slot, example <RX>.

 

 

 

 

 

Orange

 

 

There is a Stored Event in the log, which can be viewed from the front panel, or

 

 

Stored Event

 

 

 

 

retrieved via the remote control interface

 

 

 

 

 

 

 

 

 

 

 

 

Off

 

There are no Stored Events

 

 

Remote

 

 

Orange

 

 

The Unit is in Remote Mode - local monitoring is possible, but no local control

 

 

 

 

Off

 

The Unit is in Local Mode - remote monitoring is possible, but no remote control

 

 

 

 

 

Flashing

 

 

ODU FSK control has been enabled, and there is a communications fault.

 

 

 

 

 

Orange

 

 

Framing on, EDMAC on, and unit defined as Slave - local monitoring is possible,

 

 

EDMAC Mode

 

 

 

 

but no local control

 

 

 

 

 

 

 

 

 

 

 

Off

 

 

Either the unit is in Transparent mode (no framing), or the framing has been

 

 

 

 

 

 

 

 

 

 

 

 

 

 

selected, but in AUPC-only mode, or EDMAC Master configuration.

 

 

 

 

 

 

 

 

 

 

 

 

 

Orange

 

 

A Test Mode is selected (example: IF Loopback), or BERT Generator is turned on,

 

 

Test Mode

 

 

 

 

or BERT Monitor is turned on, or Spectrum Analyzer is turned on.

 

 

 

 

 

 

 

 

 

 

 

Off

 

 

There is no Test Mode currently selected, BERT Generator is off, BERT Monitor is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off, and spectrum Analyzer is off.

 

 

 

 

 

 

 

 

 

In general, the Alarm relay state will reflect the state of the Front Panel LEDs. For instance, if the Unit Status LED is red, the Unit Alarm relay will be active, etc. The one exception is the Transmit Traffic relay. This will only be activated if a Transmit Traffic Fault exists – it does not

IMPORTANT reflect the state of the TX carrier.

5–2

Page 56
Image 56
Mocomtech CDM-QX operation manual Front Panel LED Indicators, Led, Color Condition