Mocomtech CDM-QX operation manual Configuration, Select Internal if Loop, Connect External Cables

Models: CDM-QX

1 258
Download 258 pages 16.72 Kb
Page 36
Image 36

CDM-Qx Satellite Modem

Revision 5

Installation

MN/CDMQx.IOM

2.3Configuration

There are no internal jumpers to configure. All configuration is carried out entirely in software. The unit should first be configured locally, using the front panel keypad and display. The unit will ship with a default Viterbi 128 kbps, QPSK, Rate 3/4 configuration. Refer to the ‘FRONT PANEL OPERATION’ chapter for details on how to fully configure the unit for the desired operating parameters.

Note: The auto-sensing AC power supply does not require any adjustments. Simply plug in the supplied line cord, and turn on the switch on the rear panel.

2.4Select Internal IF Loop

Correct operation of the unit may be verified rapidly, without the need for externally connected equipment, providing there are at least one modulator and one demodulator. From the top-level menu, select CONFIG, then GROUP, then MODEM. This will require a modulator to be above a demodulator in the chassis. Then go back to the top- level menu; select TEST, then IF LOOP (refer to the ‘FRONT PANEL OPERATION’ chapter). The demod should synchronize, and the green RECEIVE TRAFFIC LED should illuminate. If the unit does not pass this test, call the factory for assistance.

2.5Connect External Cables

Having verified correct operation in IF loop, enter the desired configuration, and proceed to connect all external cables. If difficulties occur, please call the factory for assistance.

Observe the following:

If modulators and demodulators are to be used without grouping them as a modem, a data interface cable is required to plug into each unit. If a modulator and demodulator are grouped as a modem, the modulator must be located above the demodulator and a single data interface cable is used simply by connecting it to the demodulator.

If a modulator, demodulator, or grouped (modem) is defined as a back up unit, a data interface cable is not required to the unit or units.

Note: Each modulator has an output power level in the range -5 to -25 dBm (-5 to -45 dBm for L-Band). Even though there is a single IF output connector and a single IF input connector, all four slots are hooked up by way of internal power splitters and summers. If two modulators are turned on, the total power out will be 3 dB higher (assuming both modulators are set to the same power level). If four modulators are turned on, the total power out will be 6 dB higher (assuming all modulators are set to the same power level).

2–4

Page 36
Image 36
Mocomtech CDM-QX operation manual Configuration, Select Internal if Loop, Connect External Cables, Observe the following