Mocomtech CDM-QX operation manual Monitor„Alarms Alarms, Monitor„Alarms„Unit Unit Alarms

Models: CDM-QX

1 258
Download 258 pages 16.72 Kb
Page 107
Image 107

CDM-Qx Satellite Modem

Revision 5

Front Panel Operation

MN/CDMQx.IOM

5.6.2MONITOR

MONITOR: Alarms Rx-Params

Event-Log Stats AUPC CnC ODU

Select Alarms, Rx-Params,Event-Log,Stats, AUPC, CnC or ODU using the

arrow keys, then press ENT. The ODU menu will only appear for 70/140MHz units.

If the user selects Alarms, the following sub-menu is displayed:

5.6.2.1(Monitor„Alarms) ALARMS

The modem uses a system of Fault Prioritization. In each category of fault, only the highest priority fault is displayed. For instance, if the demodulator is

IMPORTANT unlocked, it is irrelevant if there are other receive faults present. If the demodulator then locks, but there is a fault of a lower priority present, this will then be displayed. This also holds true for the faults reported via the remote control. This system cuts down drastically on unwanted and irrelevant fault reporting. A comprehensive list of faults is shown at the end of this section.

Live Alarms:

Transmit

(◄ ►,ENT)

Receive Unit

ODU

Select Transmit, Receive, or Unit using the WXarrow keys, then press ENT. Depending on the choice , one of the following menus will be shown:

(Monitor„Alarms„Unit) – UNIT ALARMS

Unit Fault: -12 Volt PSU

is under voltage

(ENT)

The screen will indicate if there are any Unit Faults. If not, it will display ‘None’. Pressing ENT takes the user back to the previous menu.

5–53

Page 107
Image 107
Mocomtech CDM-QX operation manual Monitor„Alarms Alarms, Monitor„Alarms„Unit Unit Alarms