CDM-Qx Satellite Modem

Revision 5

Summary of Specifications

MN/CDMQx.IOM

 

A.3

Data Interfaces

 

 

 

 

Note: Features not in the initial product release are identified in parentheses.

 

 

 

 

 

 

 

EIA-530

 

Synchronous RS-232

 

 

 

 

 

 

 

 

 

EIA-530

 

EIA-422/EIA-530 DCE (Rates up to 12 Mbps)

25-pin D-sub (female)

 

(3 selectable modes)

Also supports X.21

 

 

 

 

 

V.35 DCE (Rates up to 12 Mbps)

 

 

 

 

 

Synchronous RS-232 (Rates up to 300 kbps)

 

 

 

 

 

 

 

 

 

G.703 (Balanced)

1.544

Mbps T1 (Balanced 100 Ω)

15-pin D-sub (female)

 

 

 

2.048

Mbps E1 (balanced 120 Ω)

 

 

 

 

 

 

 

 

 

G.703 (Unbalanced)

1.544

Mbps T1 (unbalanced 75 Ω)

BNC (female)

 

 

 

2.048

Mbps E1 (unbalanced 75 Ω)

 

 

 

 

 

 

 

 

 

Multi-Port G.703 (Bal)

2.048

Mbps E1 (balanced 120 Ω)

(2) 9-pin, D-sub (female)

 

1 to 4 Ports E1 w/ D&I

Note: All 4 ports must be synchronous

(2 ports per DB-9)

 

 

 

 

 

 

 

EIA-612 / 613

 

EIA-612/EIA-613 (Rates up to 20 Mbps)

50-pin, mini-D SCSI-II

 

(HSSI)

 

 

 

HSSI (female)

 

 

 

 

 

 

 

Modem Alarms

 

Relay outputs (Tx, Rx & unit faults)

15-pin D-sub (male)

 

(Present on all modules)

Demodulator I & Q test outputs (constellation)

 

 

 

 

 

Demodulator Rx Signal Level output (0 to 2.5 volts)

 

 

 

 

 

External carrier off input

 

 

 

Serial Remote Control

EIA-232 or EIA-485 modem control and monitoring

9-pin D-sub (male)

 

10/100BaseT

 

IP based monitoring & control

RJ-45

 

 

 

 

 

 

A.4

Automatic Uplink Power Control (Future)

 

 

Operating Mode

Target Eb/No range

Max AUPC range

Monitor functions

Requires Closed Network Framed mode for transport of Eb/No information from remote modem (EDMAC can be enabled or disabled)

0 to 9.9 dB at remote demod (default is 4.0 dB)

0 to 9 dB (default is 3 dB)

Remote demod Eb/No Tx power level increase

(front panel or via remote control interface)

A–5

Page 183
Image 183
Mocomtech CDM-QX operation manual Automatic Uplink Power Control Future, Hssi