CDM-Qx Satellite Modem

Revision 4

Remote Control

MN/CDMQx.IOM

 

Command

Parameter

(Instruction

Type

Code and

 

qualifier)

 

 

LNB Low

LCL=

Current Limit

 

(L-Band Unit

 

only)

 

 

 

LNB High

LCH=

Current Limit

 

(L-Band Unit

 

only)

 

 

 

LNB LO

LLO=

Frequency

 

(L-Band Unit

 

only)

 

LNB Current

N/A

(L-Band Unit

 

only)

 

 

 

LNB Voltage

N/A

(L-Band Unit

 

only)

 

 

 

Terminal Rx

N/A

Frequency

 

(L-Band Unit

 

only)

 

Arguments

for

Command or Response to Query

3bytes

3bytes

6bytes

3bytes

4bytes

10bytes

 

 

 

 

Response to

 

 

Query

 

 

Response to query

 

 

Description of arguments

 

 

Command

 

 

(Instruction

 

 

 

 

 

 

 

 

 

 

(Target to

 

 

 

 

 

(Target to

 

 

Code and

 

 

 

 

 

 

 

 

 

 

 

Controller)

 

 

 

 

 

Controller)

 

 

Qualifier)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command or Query

 

LCL=

 

 

LCL?

 

LCL=xxx

 

LNB lower alarm limit for current, in the form xxx, where xxx is

 

LCL?

 

 

 

 

(see description of

 

the current value between 10 and 400 mA.

 

LCL*

 

 

 

 

arguments)

 

 

 

 

LCL#

 

 

 

 

 

 

 

 

 

 

LCL^

 

 

 

 

 

 

 

 

Command or Query

 

 

LCH=

 

 

LCH?

 

 

LCH=xxx

 

 

LNB higher alarm limit for current, in the form of xxx, where xxx

 

 

LCH?

 

 

 

 

 

(see description of

 

 

is the current value between 50 and 600 mA.

 

 

LCH*

 

 

 

 

 

arguments)

 

 

 

 

 

LCH#

 

 

 

 

 

 

 

 

 

 

 

LCH^

 

 

 

 

 

 

 

 

Command or Query

 

 

LLO=

 

 

LLO?

 

 

LLO=xxxxxs

 

 

LNB Receive LO frequency information in the form: xxxxxx,

 

 

LLO?

 

 

 

 

 

(see description of

 

 

where: xxxxxx is the LO frequency, in the range of 3000 to

 

 

LLO*

 

 

 

 

 

arguments)

 

 

65000 MHz.

 

 

LLO#

 

 

 

 

 

 

 

 

All 0’s (000000) disables this feature.

 

 

LLO^

 

 

 

 

 

 

 

 

s is the sign for the mix (+ or – character)

 

 

 

 

 

 

 

 

 

 

 

Terminal Frequency = LNB LO RFQ

 

 

 

 

 

 

 

 

 

 

 

Example: LLO=06000- (LO is 6 GHz, high-side mix)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Query only.

 

 

N/A

 

 

LDC?

 

LDC=xxx

 

 

Indicates the value of the LNB Current, in the form: xxx, where

 

 

 

 

 

 

 

 

(see description of

 

 

xxx is between 0 and 999, units mA.

 

 

 

 

 

 

 

 

arguments)

 

 

If not available, response is 000.

 

 

 

 

 

 

 

 

 

 

 

Example: LDC=210 (LNB DC current is 210 mA)

 

 

 

 

 

 

 

 

 

 

Query only.

 

 

N/A

 

 

LDV?

 

 

LDV=xx.x

 

 

Indicates the value of the LNB Voltage, in the form: xx.x, where

 

 

 

 

 

 

 

 

(see description of

 

 

xx.x is between 0 and 20.0

 

 

 

 

 

 

 

 

arguments)

 

 

If not available, response is 00.0

 

 

 

 

 

 

 

 

 

 

 

Example: LDV=18.1 (LNB DC voltage is 18.1 volts)

 

 

 

 

 

 

 

 

 

 

Query only.

 

 

N/A

 

 

TRF?

 

 

TRF=xxxxx.xxxx

 

 

Terminal Rx Frequency, where frequency = LNB LO ± RFQ

 

 

 

 

 

 

 

 

(see description of

 

 

Resolution = 100Hz

 

 

 

 

 

 

 

 

arguments)

 

 

Returns 00000.0000 if LNB LO is zero

 

 

 

 

 

 

 

 

 

 

 

Example: TRF=11650.2249

 

 

 

 

 

 

 

 

 

 

C-46

Page 236
Image 236
Mocomtech CDM-QX operation manual Parameter Instruction Type Code Qualifier