CDM-Qx Satellite Modem

Revision 5

Front Panel Operation

MN/CDMQx.IOM

(Config„Remote„Serial„Interface„RS485) - RS-485 Bus Address

However, if either RS-485 mode is selected, the user will be further prompted:

Edit RS-485 Serial Bus Base

Address: 0245

(◄ ►,▲▼,ENT)

Edit the RS-485 bus address of this unit. This is accomplished by selecting the digit to be edited, using the efarrow keys. The value of the digit is then changed using the dcarrow keys. The user should then press ENT. The valid range of addresses is from 1 to 9999.

(Config„Remote„Serial„Baudrate)

If the user selects Baud Rate, the user is presented with the following menu:

M&C Serial

Bus Baud Rate:

19200 Baud

(▲ ▼,ENT)

Edit the baud rate of the remote control bus, connected locally to the M&C computer. The value is changed using the cdarrow keys. The user should then press ENT. Values of 2400, 4800, 9600, 19200, 38400, and 57600 baud

are possible.

Note that the asynchronous character format is FIXED at 8 data bits, 1 stop bit, no parity (8-N-1).

(Config„Remote„Ethernet)

If Ethernet is selected:

Ethernet Config: (◄ ►, ENT)